Part of the book series: IFMBE Proceedings ((IFMBE,volume 38))

  • 1076 Accesses

Abstract

Intensity Modulated Radiation Therapy and Volume Modulated Arc Therapy are now widely used in cancer treatment, but due to their complex nature each clinical plan is verified before applying on patient. Many different verification systems are available for this purpose, but because there is no regulation that would make it an obligatory, manufacturers usually don’t give such information as devices error detection threshold, repeatability etc. Therefore clinics must carry out tests before using these devices. This article is dedicated to the determining of IMRT/VMAT plan verification systems Delta4 (Scandidos, Uppsala, Sweden) error detection threshold. 10 Head & Neck IMRT and 5 esophagus VMAT clinical plans were modified with intentionally introduced errors and then verified on Delta4. Positioning errors for various moving parts (MLC, Jaws, Collimator and Gantry) together with dose related errors (MU, missing control points) were tested. The resulting gamma index was compared to the one from unmodified plan. A clear detection threshold for IMRT was detected for shift, MU, Jaws, collimator and gantry errors and for VMAT for MU and Jaws errors. No clear error detection threshold within tested error size range was found for the rest of the introduced errors.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 IFMBE

About this paper

Cite this paper

Eizentals, P., Thomas, M. (2013). Determining the Threshold of Radiotherapy Delivery Error Detection Using Delta4. In: Dekhtyar, Y., Katashev, A., Lancere, L. (eds) International Symposium on Biomedical Engineering and Medical Physics, 10-12 October, 2012, Riga, Latvia. IFMBE Proceedings, vol 38. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-34197-7_33

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-34197-7_33

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-34196-0

  • Online ISBN: 978-3-642-34197-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics