Abstract
This chapter presents information on finite element analyses (FEA) of stress distribution and contact pressure with the carpal articulation following total wrist arthroplasty (TWA) for rheumatoid arthritis (RA) of the wrist. Results from the previous analyses on the healthy and rheumatic wrist were used for comparison. A TWA model was developed based on parameters of a wrist implant named ReMotion™ total wrist system, and was then applied with the same boundary condition (static hand grip action) as the other two models. FEA has revealed that the contact pressure for the TWA model was five times lower than the RA model. Despite this encouraging finding, small variations in the amount of stress distribution were still present when compared to the healthy model. This comes to a conclusion that the used of TWA could reduces the high contact pressure induced in the RA model thus improving the diseased condition, however, there are rooms for improvement for TWA procedure to restore the biomechanical behaviour of the healthy wrist joint.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bajuri MN, Kadir MRA, Raman MM, Kamarul T (2012) Mechanical and functional assessment of the wrist affected by rheumatoid arthritis: a finite element analysis. Med Eng Phys (in press)
MacCullough MBA (2006) Clinical and biomechanical analysis of total wrist arthroplasty devices. Dissertation, University of Iowa, Iowa
Bajuri MN, Kadir MRA (2010) Biocomputational comparative study of Rheumatoid Arthritis of the wrist joint before and after arthroplasty; carpal stability analysis. In: Biomedical Engineering and Sciences (IECBES), 2010 IEEE EMBS conference on 30 Novemb 2010–2 Dec 2010, pp 270–275
Lorei MP, Figgie MP, Ranawat CS, Inglis AE (1997) Failed total wrist arthroplasty. Analysis of failures and results of operative management. Clin Orthop Relat Res 342:84–93
Huang KM, Naidu SH (2002) Total wrist arthroplasty: is there a role? Curr Opin Orthop 13(4):260–268
Adams BD (2010) Complications of wrist arthroplasty. Hand Clin 26(2):213–220
Anderson MC, Adams BD (2005) Total wrist arthroplasty. Hand Clin 21(4):621–630
Abdul-Kadir MR, Hansen U, Klabunde R, Lucas D, Amis A (2008) Finite element modelling of primary hip stem stability: the effect of interference fit. J Biomech 41(3):587–594
Dewan A, Bertolusso R, Karastinos A, Conditt M, Noble PC, Parsley BS (2009) Implant durability and knee function after total knee arthroplasty in the morbidly obese patient. J Arthroplast 24 (6, Suppl 1):89–94, e83
Menon J (1998) Universal total wrist implant: experience with a carpal component fixed with three screws. J Arthroplast 13(5):515–523
Innovations SB (2009) Surgical technique, ReMotion™ Total Wrist Implant System. Small Bone Innovations, New York
Mont MA, Seyler TM, Ragland PS, Starr R, Erhart J, Bhave A (2007) Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty. J Arthroplast 22(1):100–108
Rahman WA, Garbuz DS, Masri BA (2010) Randomized controlled trial of radiographic and patient-assessed outcomes following fixed versus rotating platform total knee arthroplasty. J Arthroplast 25(8):1201–1208
Adams BD (2006) Total wrist arthroplasty for rheumatoid arthritis. Int Congr Ser 1295:83–93
Tajdari M, Javadi M (2006) A new experimental procedure of evaluating the friction coefficient in elastic and plastic regions. J Mater Process Technol 177(1–3):247–250
Cheng H-YK, Lin C-L, Lin Y-H, Chen AC-Y (2007) Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture. Clin Biomech 22(5):510–517
Sun D, Wharton JA, Wood RJK (2009) Micro-abrasion-corrosion of cast CoCrMo—effects of micron and sub-micron sized abrasives. Wear 267(1–4):52–60
Dowson D, Fisher J, Jin ZM, Auger DD, Jobbins B (1991) Design considerations for cushion form bearings in artificial hip joints. ARCHIVE: Proc Inst Mech Eng Part H J Eng Med 1989–1996 203–210, 205(28):59–68
Zander T, Rohlmann A, Klöckner C, Bergmann G (2002) Effect of bone graft characteristics on the mechanical behavior of the lumbar spine. J Biomech 35(4):491–497
Gislason MK, Nash DH, Nicol A, Kanellopoulos A, Bransby-Zachary M, Hems T, Condon B, Stansfield B (2009) A three-dimensional finite element model of maximal grip loading in the human wrist. Proc Inst Mech Eng Part H J Eng Med 223(7):849–861
Gislason MK, Stansfield B, Nash DH (2010) Finite element model creation and stability considerations of complex biological articulation: the human wrist joint. Med Eng Phys 32(5):523–531
Carrigan SD, Whiteside RA, Pichora DR, Small CF (2003) Development of a three-dimensional finite element model for carpal load transmission in a static neutral posture. Ann Biomed Eng 31(6):718–725
Gupta A (2008) Total wrist athroplasty. J Orthop Res 37:12–16
Murali P, Bhandakkar TK, Cheah WL, Jhon MH, Gao H, Ahluwalia R (2011) Role of modulus mismatch on crack propagation and toughness enhancement in bioinspired composites. Phys Rev E 84(1):015102
Herzberg G (2011) Prospective study of a new total wrist arthroplasty: short term results. Chirurgie de la Main 30(1):20–25
Trieb K, Hofstätter S (2009) Treatment strategies in surgery for rheumatoid arthritis. Eur J Radiol 71(2):204–210
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Bajuri, M.N., Abdul Kadir, M.R. (2013). Finite Element Analysis of the Wrist Arthroplasty in Rheumatoid Arthritis. In: Computational Biomechanics of the Wrist Joint. SpringerBriefs in Applied Sciences and Technology(). Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31906-8_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-31906-8_6
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31905-1
Online ISBN: 978-3-642-31906-8
eBook Packages: EngineeringEngineering (R0)