Non-contact Pulse Wave Velocity Assessment Using Optical Methods

  • T. Pereira
  • M. Cabeleira
  • P. Matos
  • E. Borges
  • V. Almeida
  • H. C. Pereira
  • J. Cardoso
  • C. Correia
Part of the Communications in Computer and Information Science book series (CCIS, volume 273)

Abstract

The clinical relevance of pulse wave velocity (PWV), as an indicator of cardiac risk associated to arterial stiffness, has gained clinical relevance over the last years. Optic sensors are an attractive instrumental solution for this type of measurement due to their truly non-contact operation capability, which has the potential of an interference free measurement. The nature of the optically originated signals, however, poses new challenges to the designer, either at the probe design level as at the signal processing required to extract the timing information that yields PWV. In this work we describe the construction of two prototype optical probes and discuss their evaluation using three algorithms for pulse transit time (PTT) evaluation. Results, obtained in a dedicated test bench, that is also described, demonstrate the possibility of measuring pulse transit times as short as 1ms with less than 1% error.

Keywords

Optical probes Photodiode Waveform distension Pulse transit time Pulse wave velocity 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Bramwell, J., Hill, A.: The velocity of the pulse wave in man. Proc. Roy. Soc. Lond. [Biol.] 93, 298–306 (1922)CrossRefGoogle Scholar
  2. 2.
    Rajzer, M., et al.: Comparison of aortic pulse wave velocity measured by three techniques: Complior, Spymocor and Arteriograph. J. Hypertens 26, 2001–2007 (2008)CrossRefGoogle Scholar
  3. 3.
    Laurent, S., et al.: Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur. Heart. J. 27, 2588–2605 (2006)CrossRefGoogle Scholar
  4. 4.
    Xu, M.: Local Measurement of the Pulse Wave Velocity using Doppler Ultrasound. Massachusetts Institute of Tecnology (2002)Google Scholar
  5. 5.
    Kips, J., et al.: The use of diameter distension waveforms as an alternative for tonometric pressure to assess carotid blood pressure. Physiol. Meas. 31(2010), 543–553 (2010)CrossRefGoogle Scholar
  6. 6.
    Vermeersch, S.J., et al.: Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects. Physiol. Meas. 29, 1267–1280 (2008)CrossRefGoogle Scholar
  7. 7.
    Kazanavicius, E., Gircys, R.: Mathematical Methods for determining the foot point of the Arterial Pulse Wave and Evaluation of Proposed Methods. Information Technology and Control (2005) ISSN 1392 – 124XGoogle Scholar
  8. 8.
    Azaria, M., Hertz, D.: Time delay estimation by generalized cross correlation methods. IEEE Trans. Acoustics, Speech, and Signal Processing ASSP-32, 280–285 (1984)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2013

Authors and Affiliations

  • T. Pereira
    • 1
  • M. Cabeleira
    • 1
  • P. Matos
    • 1
  • E. Borges
    • 1
  • V. Almeida
    • 1
  • H. C. Pereira
    • 1
    • 2
  • J. Cardoso
    • 1
  • C. Correia
    • 1
  1. 1.Instrumentation Center, Physics DepartmentUniversity of CoimbraCoimbraPortugal
  2. 2.ISA- Intelligent Sensing AnywhereCoimbraPortugal

Personalised recommendations