Abstract
The demand for less invasive procedures and bonesparing hip implants has led to the development of short stem prostheses. Various types of hip prostheses are called short stem, although they are based on different principles. Shortened conventional, short anatomic, double taper type, and neck implants rely on different fixation points in the femur and need to be reviewed individually. Short stem prostheses all have in common that they preserve the greater trochanter and part of the femoral neck, which leads to a curved implantation technique and is well suited for a minimally invasive procedure. The cementless fixed prostheses provide a high primary stability to allow immediate weight bearing (Eingartner 2007).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Braun A, Sabah A (2009) Two-year results of a modular short hip stem prosthesis – a prospective study. Z Orthop Unfall 147:700–706
Braun A, Lazovic D, Zigan R (2007) Modular short-stem prosthesis in total hip arthroplasty: implant positioning and the influence of navigation. Orthopedics 30:S148–152
D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315–321
D’Lima DD, Chen PC, Colwell CW Jr (2001) Optimizing acetabular component position to minimize impingement and reduce contact stress. J Bone Joint Surg Am 83:87–91
Dorr LD, Malik A, Dastane M, Wan Z (2009) Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res 467:119–127
Eingartner C (2007) Currents trends in total hip arthroplasty. Orthop Traumatol Rehabil 9:8–14
Lazovic D, Zigan R (2006/7) Navigation of short-stem implants. Orthopedics 29:S 125–129. Erratum in: Orthopedics 30:327
Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip replacement arthroplasties. J Bone Joint Surg Am 60:217–220
Matsushita A, Nakashima Y, Fujii M, Sato T, Iwamoto Y (2010) Modular necks improve the range of hip motion in cases with excessively anteverted or retroverted femurs in THA. Clin Orthop Relat Res 468:3342–3347
Milecki M, Kowalczewski J, Wielopolski A, Obrebski M, OkoŠT, Marczak D (2008) Modular short-stem prosthesis in total hip arthroplasty – preliminary report (in Polish). Chir Narzadow Ruchu Ortop Pol 73:244–247
Morrey BF (1989) Short-stemmed uncemented femoral component for primary hip arthroplasty. Clin Orthop Relat Res 249:169–175
Morrey BF, Adams RA, Kessler M (2000) A conservative femoral replacement for total hip arthroplasty. A prospective study. J Bone Joint Surg Br 82:952–958
Müller M, Crucius D, Perka C, Tohtz S (2011) The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty. Int Orthop (SICOT) 35:981–987
Renkawitz T, Haimerl M, Dohmen L, Gneiting S, Wegner M, Ehret N, Buchele C, Schubert M, Lechler P, Woerner M, Sendtner E, Schuster T, Ulm K, Springorum R, Grifka J (2011) Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial. BMC Musculoskelet Disord 12:192
Renkawitz T, Haimerl M, Dohmen L, Gneiting S, Lechler P, Woerner M, Springorum HR, Weber M, Sussmann P, Sendtner E, Grifka J (2012) The association between femoral tilt and impingement-free range-of-motion in total hip arthroplasty. BMC Musculoskelet Disord 13:65
Sariali E, Mouttet A, Pasquier G, Durante E (2009a) Three-dimensional hip anatomy in osteoarthritis. Analysis of the femoral offset. J Arthroplasty 24:990–997
Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009b) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br 91:333–340
Seki M, Yuasa N, Ohkuni K (1998) Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 16:513–517
Sendtner E, Tibor S, Winkler R, Wörner M, Grifka J, Renkawitz T (2010) Stem torsion in total hip replacement. Acta Orthop 81:579–582
Wassilew GI, Perka C, Koenig C, Janz V, Asbach P, Hasart O (2012) 3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty. Orthopedics 33:48–51
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Lazovic, D. (2013). Short Stem Navigation and Optimized Range of Motion. In: Haaker, R., Konermann, W. (eds) Computer and Template Assisted Orthopedic Surgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29728-1_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-29728-1_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-29727-4
Online ISBN: 978-3-642-29728-1
eBook Packages: MedicineMedicine (R0)