Abstract

The flow resistance of stent with different shape of wire cross-section can be considered as a factor that influences the condition of inflow and outflow through the stent wire. Different from the traditional stents, a novel stent with triangular wire cross-section was proposed, and numerical simulations were performed to compare the hemodynamic effect of the novel stent with that of traditional ones. Three constructed aneurysm models were treated with a different kind of stent separately, including one with bare circular wire cross-section stent (named CM), one with bare rectangular wire cross-section stent (named RM), one with bare triangular cross-section stent (named TM). An unstented aneurysm model was also constructed to serve as a control (named UM). Numerical simulations of the fluid-structure interaction in these four models were performed under the same boundary conditions using finite element method. The simulation results demonstrated the resistance of the novel stent is lower than RM stent, but higher than that of CM stent. TM stent attributes a higher velocity decreasing and a longer turnover time compared with CM stent. The distribution of wall shear stress indicated the possibility of aneurysm development along the distal wall was higher than the proximal wall, and the top of aneurysm was in the highest risk of rupture.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Zeng, K., Qiao, Ak. (2013). Numerical Simulation of Intracranial Saccular Aneurysm Treated with Stent with Triangular Wire Cross-Section. In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_40

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-29305-4_40

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-29304-7

  • Online ISBN: 978-3-642-29305-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics