Fontan procedure is one of the common surgical treatment of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. Pulmonary blood flow in the Fontan circulation is lower than in healthy subjects, and the central venous pressure may elevate. In this study, we developed a mechanical circulatory assist device for the extracardiac conduit for Fontan circulation and examined its driving method in the mock pediatric pulmonary circulatory system. We used shape memory alloy (SMA) fiber as an actuator of the device. The SMA actuator wrapped the extracardiac conduit between inferior vena cava and pulmonary artery. We designed two different types of the circulatory assist devices. We drove these devices in two different modes by the synchronized and sequential motions. The flow volume was 10mL/min against a load of 10mmHg, and the maximum contractile force indicated 60mmHg in the mock test. These results suggested the effective mechanical assistance for Fontan pulmonary circulation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Yamada, A. et al. (2013). Preliminary Design of the Mechanical Circulation Assist Device for Fontan Circulation using Shape Memory Alloy Fibers. In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_33

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-29305-4_33

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-29304-7

  • Online ISBN: 978-3-642-29305-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics