Abstract
Summarized the FCL practical research which faces to the key technical problems, briefly introduces the study of magnetic valve controllable reactor type fault current limiter principle, and the simulation results validate the superiority of the limiting current performance.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Yuan, J., Liu, W., Dong, Q.: Northwest power grid short-circuit current restrictions of Electrical Engineering, vol. (10) (2007)
Yuan, Q.: Future of Shanghai power grid short circuit current control status and countermeasures of Electrical Engineering, vol. (02) (2005)
Wu, D.: Limit the level of the bulk power system short-circuit current measures of research. Master thesis. Zhejiang University (2005)
Li, M.: Zhenjiang operation of the grid hierarchy partitions. Master thesis. Southeast University (2006)
Chen, Y.: Big power grid short-circuit current restrictions research. Master’s degree thesis. Zhejiang university (2008)
Hao, Z., Jiang, D., Cai, Y.: New solid-state fault current limiter on power system transient stability. The Effect of Automation of Electric Power Systems (08) (2004)
Hao, Z.: Solid fault fault current limiter on power system operation effects. Master’s degree thesis. Zhejiang university (2004)
Liu, H., Li, Q., Xu, L.: Zinc oxide arrestor type fault fault-current limiter on power system transient stability. The Influence of Electric Power Automation Equipment (08) (2007)
Yang, Z.: Superconducting fault current limiter on power system transient stability of analysis on the influence. Master’s degree thesis. University of north China electric power (hebei) (2007)
Gu, X., Yang, Z.: A symmetric when short-circuit fault circuit reactance type FCL is transient stability of the influence of the journal. An Electrician Technology (09) (2009)
Liu, H., Li, Q., Lou, J.: Inductance type in a circuit breaker FCL resuming voltage current-rising-rate influence. Electrician Technology Journal 22(12), 84–91 (2007)
Liu, H., Li, Q., Zou, L.: Installation fault FCL is hidden power transmission lines and single phase reclosing arc characteristic strategy. Chinese Electrical Engineering (31) (2008)
Geng, S., Zhang, J., Zhang, M.: Network (FCL type of high voltage circuit breaker open circuit fault). The Influence of Power System Protection and Control (18) (2009)
Hong, J., Guan, Y., Xu, G.: Different fault serial resonant FCL to restore the influence of high voltage circuit breaker voltage. High Voltage Apparatus (05) (2009)
Zhou, X., Xu, X., Ma, Y.: Superconducting fault current limiter on the influence of the relay protection. China Electric Power (03) (2007)
He, Y., Chen, X., Tang, Y.: Superconducting fault current limiter for automatic reclosing and after the influence. High Voltage Technology (10) (2008)
Zou, L., Li, Q., Liu, H.: Plan and fault current limiter and fault of interim resistance grounding distance protection compensation algorithm. Power Automation Equipment (03) (2009)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag GmbH Berlin Heidelberg
About this chapter
Cite this chapter
Shi, C. (2012). Fault Current Limit (FCL) Technology (Magnetic Valve Controlled Reactor-Type Fault Current Limiter Principle and Simulation). In: Tan, H. (eds) Knowledge Discovery and Data Mining. Advances in Intelligent and Soft Computing, vol 135. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-27708-5_19
Download citation
DOI: https://doi.org/10.1007/978-3-642-27708-5_19
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-27707-8
Online ISBN: 978-3-642-27708-5
eBook Packages: EngineeringEngineering (R0)