Abstract
The first vitamin-doped HXLPE materials were recently introduced into clinical practice. The protection of HXLPE with vitamin E leads to excellent oxidation resistance. It has a number of important benefits for the material properties, most importantly, the effective prevention of any loss of toughness over the entire life span of the implant. The wear rates of hip simulator testing remain very low even when the implants are subjected to accelerated ageing up to times corresponding to 40 years in vivo.
This paper is the first to report on the clinical performance of vitamin E-blended HXLPE hip implants. From a cohort of 553 cases (528 patients), a 1-year follow-up is available for 164 cases. All patients showed stable implant fixation during the last follow-up performed. There was no sign of early loosening of the cup.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Stafford GH, Islam SU, Witt JD (2011) Early to mid-term results of ceramic-on-ceramic total hip replacement: analysis of bearing-surface-related complications. J Bone Joint Surg Br 93(8):1017–1020
Affatato S, Traina F, Toni A (2011) Microseparation and stripe wear in alumina-on-alumina hip implants. Int J Artif Organs 34(6):506–512
Stanat SJ, Capozzi JD (2011) Squeaking in third- and fourth-generation ceramic-on-ceramic total hip arthroplasty, meta-analysis and systematic review. J Arthroplasty [Epub ahead of print] doi: 10.1016/j.arth.2011.04.031
Aroukatos P, Repanti M, Repantis T et al (2010) Immunologic adverse reaction associated with low-carbide metal-on-metal bearings in total hip arthroplasty. Clin Orthop Relat Res 468(8):2135–2142
Catelas I, Wimmer MA (2011) New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am 93(Suppl 2):76–83
Langton DJ, Jameson SS, Joyce TJ et al (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br 92(1):38–46
Langton DJ, Jameson SS, Joyce TJ et al (2011) Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg Br 93(8):1011–1016
Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17(5):649–661
Kurtz SM, Gawel HA, Patel JD (2011) History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 469(8):2262–2277
Kuzyk PRT, Saccone M, Sprague S et al (2011) Cross-linked versus conventional polyethylene for total hip replacement. J Bone Joint Surg Br 93(5):593–600
Currier BH, Van Citters DW, Currier JH et al (2010) In vivo oxidation in remelted highly cross-linked retrievals. J Bone Joint Surg Am 92(14):2409–2418
Lerf R, Zurbrügg D, Delfosse D (2010) Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials 31(13):3643–3648
Oral E, Moratoglu OK (2011) Vitamin E diffused, highly crosslinked UHMWPE – a review. Int Orthop 35(2):215–223
Bracco P, Oral E (2011) Vitamin E-stabilized UHMWPE for total joint implants – a review. Clin Orthop Relat Res 469(8):2286–2293
Zurbrügg D, Abt NA (2003) Comparison between in vivo aging, shelf and accelerated aging of UHMWPE based on the theory of oxidation kinetics. Poster at 18th European conference on biomaterials, Stuttgart, 1–4 Oct 2003
Noordin S, Schmalzried TP, Campbell P et al (1997) Synovial fluid from patients with prosthetic joint arthroplasty: protein concentration and in vivo wear of polyethylene. In: Transactions of the 43rd annual meeting of the Orthopaedic Research Society, San Francisco, 1997, vol 22, p 769
Saari H, Santavirta S, Nordstrom D et al (1993) Hyaluronate in total hip replacement. J Rheumatol 20(1):87–90
Pakvis D, Biemond L, van Hellemondt G et al (2010) A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop 35(10):1445–1451
Ihle M, Mai S, Pfluger D et al (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg Br 90(10):1284–1290
Ihle M, Mai S, Siebert WE (2010) Treatment for acetabular dysplasia using the uncemented RM acetabular component – a 20 year follow-up. Hip Int 20(1):94–101
Author information
Authors and Affiliations
Corresponding authors
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 EFORT
About this chapter
Cite this chapter
Beck, M. et al. (2012). Oxidation Prevention with Vitamin E in a HXLPE Isoelastic Monoblock Pressfit Cup: Preliminary Results. In: Knahr, K. (eds) Total Hip Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-27361-2_3
Download citation
DOI: https://doi.org/10.1007/978-3-642-27361-2_3
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-27360-5
Online ISBN: 978-3-642-27361-2
eBook Packages: MedicineMedicine (R0)