Abstract
Partial discharge of power cable is a serious hidden danger to shorten the life of cable and to lower power supply reliability. It is difficult to sample the partial discharge signal because of its weakness of 1mV and high spectrum of 300MHz. Data acquisition PXI5154, Multi-channel switch PXI2593 and the computer system produced by National Instrument Co., LTD are used to be the platform for data sampling. Data sampling & communication subsystem and client subsystem are designed to realize channel selection, data sampling and storing, data displaying, history data replaying, information setting and user authority management.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Guo, J., Wu, G., Zhang, X., Shu, W.: The present situation and development of partial discharge detection technology. Transactions of China Electrotechnical Society (2005)
Liu, Y.: The electrical positioning and diagnosis of the power transformer partial discharge. North China Electric Power University, Hebei (2005)
Huang, T.: The research of the positioning method that power cables partial discharge. Xian Electronics Science and Technology University, Xian (2009)
Xu, S.: The research of the wavelet analysis applied in transformer partial discharge on-line monitoring. Shanghai Jiao Tong University, Shanghai (2001)
Qiu, C., Naiqing, W., et al.: The techniques of the electrical equipment partial discharge and testing. China Machine Press, Beijing (1994)
Stone, G.C., Sedding, H.G., Costello, M.J.: Application of partial discharge testing to motors and generator stator winding maintenance. IEEE Trans. on IAS 32(2), 459–464 (1996)
Stone, G.C., Sedding, H.G.: In-service evaluation of motor and generator stator winding using partial discharge tests. IEEE Trans. on IAS 31(2), 299–303 (1995)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Yang, G., Wang, F., Cui, S., Zhao, L. (2011). Design and Implementation of Data Acquisition for Partial Discharge in Power Cable. In: Wu, Y. (eds) Advances in Computer, Communication, Control and Automation. Lecture Notes in Electrical Engineering, vol 121. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-25541-0_25
Download citation
DOI: https://doi.org/10.1007/978-3-642-25541-0_25
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-25540-3
Online ISBN: 978-3-642-25541-0
eBook Packages: EngineeringEngineering (R0)