Skip to main content
  • 1610 Accesses

Abstract

Recalling the expression “all is not gold that glitters”, increased uptake is not necessarily pathological. Indeed, normal bone scintigraphs are often altered or modified by physiological or anatomical factors, imitating pathology (Howarth et al. 1996). For example, the tuberosity of the humerus and proximal tibia, to which the deltoid and quadriceps muscles are attached, respectively, may accumulate tracer intensely due to constant physical stress. Tracer uptake is normally increased in growing bones, either locally in the physes (Figs. 4.13 and 4.15) or generally in the entire skeleton, and also in anatomical variants. Modest tracer uptake may be observed in secondary ossification centers that have recently been fused (Fig. 4.31A). A number of artifacts can be produced by various technical factors related to kit preparation or intravenous injection of radiopharmaceuticals, attenuation of gamma rays, or the function of the gamma camera and computer systems (Hung et al. 1996; Forstrom et al. 1996; O’Connor 1996).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References


  • Ajmani SK, Lerner SR, Pircher FJ (1977) Bone scan artifact caused by hyperhidrosis: case report. J Nucl Med 18:801–802


    PubMed  CAS  Google Scholar 

  • Bahk YW, Park YH, Chung SK, et al (1994) Pinhole scintigraphic sign of chondromalacia patellae in older subjects: a prospective assessment with differential diagnosis. J Nucl Med 35:855–862


    PubMed  CAS  Google Scholar 

  • Ceylan E, Caner B (2003) Evolution of hyperostosis frontalis interna butterfly sign demonstrated by bone scan. Clin Nucl Med 28:78–79


    Article  PubMed  Google Scholar 

  • Daenen B, Preidler KW, Padmanabhan S, et al (1997) Symptomatic herniation pits of the femoral neck: anatomic and clinical study. AJR Am J Roentgenol 168:149–153


    PubMed  CAS  Google Scholar 

  • Desaia A, Intenzo C (1984) The “tourniquet effect”. J Nucl Med 25:697–699


    PubMed  CAS  Google Scholar 

  • Eggli DF, Tulchinsky M (1996) Normal planar bone scan. In: Collier BD, Fogelman I, Rosenthal L (eds) Skeletal nuclear medicine, 1st edn. Mosby‑Year Books, St. Louis, pp 23–42


    Google Scholar 

  • Fink‑Bennett D, Johnson J (1986) Stippled ribs: a potential pitfall in bone scan interpretation. J Nucl Med 27:216–218


    CAS  Google Scholar 

  • Fink‑Bennett D, Vicuna‑Rios J (1980) The deltoid tuberosity – a potential pitfall (the “delta” sign) in bone‑scan interpretation: concise communication. J Nucl Med 21:211–212


    PubMed  CAS  Google Scholar 

  • Forstrom LA, Dunn WL, O’Connor MK, et al (1996) Technical pitfalls in image acquisition, processing, and display. Semin Nucl Med 26:278–294


    Article  PubMed  CAS  Google Scholar 

  • Gray HW, Krawnow AZ (1996) Soft tissue uptake of bone agents. In: Collier BD, Fogelman I, Rosenthal L (eds) Skeletal nuclear medicine, 1st edn. Mosby‑Year Books, St. Louis, pp 375–399


    Google Scholar 

  • Harbert J, Desai R (1985) Small calvarial bone scan foci – normal variations. J Nucl Med 26:1144–1148


    PubMed  CAS  Google Scholar 

  • Hirano T, Otake H, Ichikawa K, et al (1998) Chronic mastoid sinusitis mimicking metastatic disease demonstrated by Tc‑99 m HMDP bone scintigraphy. Clin Nucl Med 23:327–328


    Article  PubMed  CAS  Google Scholar 

  • Howarth DM, Forstrom LA, O’Connor MK, et al (1996) Patient‑related pitfalls and artifacts in nuclear medicine imaging. Semin Nucl Med 26:295–307


    Article  PubMed  CAS  Google Scholar 

  • Hung JC, Ponto JA, Hammes RJ (1996) Radiopharmaceutical‑related pitfalls and artifacts. Semin Nucl Med 26:208–255


    Article  PubMed  CAS  Google Scholar 

  • Jaszczak RJ, Coleman RE (1985) Single photon emission computed tomography (SPECT) principles and instrumentation. Invest Radiol 20:897–910


    Article  PubMed  CAS  Google Scholar 

  • Kipper MS, Alaxraki NP, Feiglin DH (1982) The “hot” patella. Clin Nucl Med 71:28–32


    Article  Google Scholar 

  • Kirsh JC, Tepperman PS (1985) Assessment of hand blood flow: a modified technique. AJR Am J Roentgenol 144:781–783


    PubMed  CAS  Google Scholar 

  • Lawson JP, Ogden JA, Sella E, Barwick KW (1984) The painful accessory navicular. Skeletal Radiol 12:250–266


    Article  PubMed  CAS  Google Scholar 

  • Lim ST, Sohn MH, Kwak JY, et al (2001a) Skeletal metastases mimicking bilateral “delta sign” on Tc‑99 m MDP bone scintigraphy. Clin Nucl Med 26:573–574


    Article  PubMed  CAS  Google Scholar 

  • Lim ST, Sohn MH, Yim CY (2001b) Pregnancy‑induced uterine blush detected incidentally by three‑phase bone scintigraphy. Clin Nucl Med 26:654


    Article  PubMed  Google Scholar 

  • Mandell GA, Harcke HT, Sharkey C, et al (1986) Uterine blush in multiphase bone imaging. J Nucl Med 27(1):51–55


    PubMed  CAS  Google Scholar 

  • Murray IP, Frater CJ (1994) Prominence of the C2 vertebra on SPECT. A normal variant. Clin Nucl Med 19:855–859


    Article  PubMed  CAS  Google Scholar 

  • O’Connor MK (1996) Instrument- and computer‑related problems and artifacts in nuclear medicine. Semin Nucl Med 26:256–277


    Article  PubMed  Google Scholar 

  • Orzel JA, Rosenbaum DM, Weinberger E (1989) “Tourniquet effect” can alter delayed static bone scan. AJR Am J Roentgenol 152:896


    PubMed  Google Scholar 

  • Pitt MJ, Graham AR, Shipman JH, et al (1982) Herniation pit of the femoral neck. AJR Am J Roentgenol 138:1115–1121


    PubMed  CAS  Google Scholar 

  • Rao BK, Lieberman LM (1980) Parietal thinning: a cause for photopenia on bone scan. Clin Nucl Med 5:313


    Article  PubMed  Google Scholar 

  • Senda K, Itoh S (1987) Evaluation of diffusely high uptake by the calvaria in bone scintigraphy. Ann Nucl Med 1:23–26


    Article  PubMed  CAS  Google Scholar 

  • Sty JR, Starshak RJ (1983) Skull scintigraphy. Parietal foramina. Clin Nucl Med 8:87


    Article  PubMed  Google Scholar 

  • Tsai SC, Kao CH, Lin WY, et al (1999) Intestinal accumulation of Tc‑99 m MDP on bone scan. Semin Nucl Med 29:80–81

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yong-Whee Bahk .

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Bahk, YW., Sohn, MH. (2013). Normal Variants and Artifacts. In: Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-25144-3_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-25144-3_5

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-25143-6

  • Online ISBN: 978-3-642-25144-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics