Skip to main content

An Instrumentation Design for Microsignal Output from Piezoresistive Microcantilever Biosensor for Human Stress

  • Conference paper
5th European Conference of the International Federation for Medical and Biological Engineering

Abstract

This paper concerns the development of a potentiometric instumentation circuit for integration with a PZR microcantilever biosensor to detect human stress. It embodies the design of transduction, filtering, stabilization and linearization of micro-signals from a biosensor. The sensing principle is based on immobilization of the bioreceptor to produce a biochemical reaction. The novel biosensor integrated with the potentiometric instrumentation converts this biochemical event into a measurable electrical signal. Input is the level of salivary alpha amylase activity corresponds to human stress level. The first phase transduces the changes in enzymatic reaction into resistivity. The subsequent stages condition the signal to attain an output of 0-5V from a potentiometric input of 108.6 to -100mV, equivalent to sensor resistivity range of 1.2-1.3kΩ. The design for filtering phase employs a first order high and low pass filter to capture stress signals, known with frequency between 0.15-0.4Hz. Performance of the circuit is evaluated with simulation and experimental study. On the average, discrepancy less than 3.69%, 4.5% and 3.7% is found between simulation and experimental results for the transduction, filtering and linearization phase respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 449.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Khuan, L.Y. et al. (2011). An Instrumentation Design for Microsignal Output from Piezoresistive Microcantilever Biosensor for Human Stress. In: Jobbágy, Á. (eds) 5th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings, vol 37. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-23508-5_21

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-23508-5_21

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-23507-8

  • Online ISBN: 978-3-642-23508-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics