Abstract
Return voltage measurement (RVM) is an effective dielectric response test method and has been used to evaluate aging status of solid insulation. In the process of field test, the polarization spectrum obtained is non-standard which is affected by many factors, and the insulation status of dielectric is hard to judge. Factors that affect field test return voltage polarization spectrum were analyzed, method of judging and explaining the non-standard polarization spectrum was provided. Reliability and preciseness of judging solid insulation status with polarization spectrum were improved. This method have great reference value in engineering practice.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Urbani, G.M., Brooks, R.S.: Using the recovery voltage method to evaluate aging in oil-paper insulation. In: IEEE International Conference on Conduction and Breakdown in Solid Dielectrics, Sweden (1998)
Csepes, I., Hamos, R., Brooks, V.: Practical Foundations of the RVM (Recovery Voltage Method for Oil/Paper Insulation Diagnosis) Annual Report. In: Conference on Electrical Insulation and Dielectric Phenomena, vol. 1, pp. 345–355. IEEE, Los Alamitos (1998)
Aschenbrenner, V., Ueik, T.: The possibilities and limits of estimation of ageing degree of paper-oil insulation in power transformers by recovery voltage method. In: Eighth International Conference on Dielectric Materials, Measurements and Applications, September 17-21, pp. 335–340 (2000)
Tao, Z., Jinding, C.: Research on moisture content analysis of insulation pressboard in oil-paper transformer using polarization Spectrum. Adv. Tech. Of Elec. Eng.& Energy 28(4), 46–49 (2009)
Saha, T.K., Purkait, P.: Impact of the condition of oil on the polarisation based diagnostics for assessing the condition of transformers insulation. In: IEEE Power Engineering Society General Meeting, June 12-16, vol. 2, pp. 1881–1886 (2005)
Mitchinson, P.M., Lewin, P.L., Chen, G.C., Jarman, P.: An experiment for evaluating the scale effect of moisture on high voltage transformer insulation. In: Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, pp. 218–221 (2006)
Bognar, A., Csepes, G., Kalocsai, L., Kispal, I.: Spectrum of polarization phenomena of long time-constant as a diagnostic method of oil-paper insulating system. In: Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials, vol. 2, pp. 723–726. IEEE, Xi’an China (1991)
Caisheng, W., Zhifang, Z., Jinfa, C.: A new method for field detection of general status of oil-paper insulation system in power transformer. High Voltage
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Jiang, X., Fang, L., Zhang, T. (2011). A Diagnostic Method of Transformer Insulation Status with Abnormal Polarization Spectrum. In: Zhang, J. (eds) Applied Informatics and Communication. ICAIC 2011. Communications in Computer and Information Science, vol 227. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-23226-8_32
Download citation
DOI: https://doi.org/10.1007/978-3-642-23226-8_32
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-23225-1
Online ISBN: 978-3-642-23226-8
eBook Packages: Computer ScienceComputer Science (R0)