Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 34))

  • 1741 Accesses

Abstract

This paper evaluates the signal-to-noise ratio, the time stability, and the phase difference of the sampling in the experimental ultrasound scanner SARUS: A synthetic aperture, real-time ultrasound system. SARUS has 1024 independent transmit and receive channels and is capable of handling 2D probes for 3D ultrasound imaging. It samples at 12 bits per sample and has a sampling rate of 70 MHz with the possibility of decimating the sampling frequency at the input. SARUS is capable of advanced real-time computations such as synthetic aperture imaging. The system is built using field-programmable gate arrays (FPGAs) making it very flexible and allowing implementation of other real-time ultrasound processing methods in the future.

For conventional B-mode imaging, a penetration depth around 7 cm for a 7 MHz transducer is obtained (signal-to-noise ratio of 0 dB), which is comparable to commercial ultra-sound scanners. Furthermore, the jitter between successive acquisitions for flow estimation is around 1.41 ps with a stan-dard deviation of 48.3 ps. This has a negligible impact (0.03%) on the flow measurement. Additionally, for the phase of the sampling, it is shown that the small differences between different channels (on average 111 ps for a 70 MHz sampling clock) are deterministic and can therefore be compensated for.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Stuart, M.B., Tomov, B.G., Jensen, J.A. (2011). Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound System. In: Dremstrup, K., Rees, S., Jensen, M.Ø. (eds) 15th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics (NBC 2011). IFMBE Proceedings, vol 34. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21683-1_40

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-21683-1_40

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-21682-4

  • Online ISBN: 978-3-642-21683-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics