Abstract
In the chapter on hardware first the commercially available micro-imaging system and low-field system employed in the applications are presented. The latter is equipped with a one-axis bipolar gradient system. Properties of common permanent-magnet materials are compiled. Specifically designed parts described in some detail include an actively shielded gradient system for the transverse field geometry encountered in permanent-magnet systems, an inside-out setup, as well as a simple, compact, and efficient Halbach magnet. A common probe-matching network is analyzed in an intuitive representation used in electrical engineering and applied to a simple solenoid operating at 10 MHz. The chapter is concluded by the description of a flow loop used for rheological and online measurements.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
- 1.
A network analyzer capable of measuring the S 11 parameter including phase is sufficient. The impedance of the device under test is conveniently represented in a Smith chart. A cable must be used to connect the analyzer to the receiving element. Its influence on the measured impedance can be corrected automatically if the analyzer has an “extended port” option.
References
Blümich B (2000) NMR imaging of materials. Clarendon Press, Oxford
Blümich B, Anferov V, Anferova S, Klein M, Fechete R, Adams M, Casanova F (2002) Simple NMR-MOUSE with a bar magnet. Concept Magnetic Res 15(4):255–261. DOI 10.1002/cmr.10046
Blümich B, Blümler P, Eidmann G, Guthausen A, Haken R, Schmitz U, Saito K, Zimmer G (1998) The NMR-mouse: Construction, excitation, and applications. Magn Reson Imaging 16(5–6):479–484
Blümich B, Casanova F, Appelt S (2009) NMR at low magnetic fields. Chem Phys Lett 477(4–6):231–240. DOI 10.1016/j.cplett.2009.06.096
Blümich B, Mauler J, Haber A, Perlo J, Danieli E, Casanova F (2009) Mobile NMR for geophysical analysis and materials testing. Pet Sci 6(1):1–7. DOI 10.1007/ s12182-009-0001-4
Bowtell R, Mansfield P (1990) Screened coil designs for NMR imaging in magnets with transverse field geometry. Meas Sci Technol 1(5):431–439
Callaghan PT (1991) Principles of nuclear magnetic resonance microscopy. Clarendon Press, Oxford
Danieli E, Mauler J, Perlo J, Blümich B, Casanova F (2009) Mobile sensor for high resolution NMR spectroscopy and imaging. J Magn Reson 198(1):80–87. DOI 10.1016/ j.jmr.2009.01.022
Danieli E, Perlo J, Bluemich B, Casanova F (2010) Small magnets for portable NMR spectrometers. Angew Chem Int Edit 49(24):4133–4135. DOI 10.1002/anie.201000221
Fukushima E, Roeder SBW (1981) Experimental pulse NMR: A nuts and bolts approach. Addison-Wesley, Reading, MA
Hardy EH, Mertens D, Hochstein B, Nirschl H (2009) Compact NMR-based capillary rheometer. In: Fischer P, Pollard M, Windhab EJ (eds) Proceedings of the 5th ISFRS, pp 94–97. http://www.isfrs.ethz.ch/proc/2009_proc. 5th International symposium on food rheology and structure, ETH Zrich, Zrich, 15–18 June 2009
Hardy EH, Mertens D, Hochstein B, Nirschl H (2009) Kompaktes, NMR-gesttztes Kapillarrheometer. Chem Ing Tech 81(8):1100–1101
Hills B, Wright K, Gillies D (2005) A low-field, low-cost Halbach magnet array for open-access NMR. J Magn Reson 175(2):336–339. DOI 10.1016/j.jmr.2005.04.015
Jackson JA, Burnett LJ, Harmon JF (1980) Remote (inside-out) NMR.3. Detection of nuclear magnetic-resonance in a remotely produced region of homogeneous magnetic-field. J Magn Reson 41(3):411–421
Jin J (1999) Electromagnetic analysis and design in magnetic resonance imaging. CRC Press, Boca Raton
Kuhns PL, Lizak MJ, Lee SH, Conradi MS (1988) Inductive coupling and tuning in NMR probes – Applications. J Magn Reson 78(1):69–76
Manz B, Coy A, Dykstra R, Eccles CD, Hunter MW, Parkinson BJ, Callaghan PT (2006) A mobile one-sided NMR sensor with a homogeneous magnetic field: The NMR-MOLE. J Magn Reson 183(1):25–31. DOI 10.1016/j.jmr.2006.07.017
McDonald PJ, Aptaker PS, Mitchell J, Mulheron M (2007) A unilateral NMR magnet for sub-structure analysis in the built environment: The surface GARField. J Magn Reson 185(1):1–11. DOI 10.1016/j.jmr.2006.11.001
McDowell A, Fukushima E (2008) Ultracompact NMR: H-1 spectroscopy in a subkilogram magnet. Appl Magn Reson 35(1):185–195. DOI 10.1007/ s00723-008-0151-3
Mertens D, Hardy EH, Hochstein B, Guthausen G (2009) A low-field-NMR capillary rheometer. In: Guojonsdottir M, Belton P, Webb G (eds) Magnetic resonance in food science: Challenges in a changing world, pp 81–88. 9th International conference on applications of magnetic resonance in food science, Reykjavik, Iceland, 15–17 September 2008
Mispelter J, Lupu M, Briguet A (2006) NMR probeheads for biophysical and biomedical experiments : Theoretical principles and practical guidelines. Imperial College Press, London
Perlo J, Casanova F, Blümich B (2004) 3D imaging with a single-sided sensor: An open tomograph. J Magn Reson 166(2):228–235. DOI 10.1016/j.jmr.2003.10.018
Perlo J, Casanova F, Blümich B (2007) Ex situ NMR in highly homogeneous fields: H-1 spectroscopy. Science 315(5815):1110–1112. DOI 10.1126/science.1135499
Raich H, Blumler P (2004) Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR mandhalas. Concept Magn Res B 23B(1):16–25. DOI 10.1002/cmr.b.20018
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Hardy, E.H. (2012). Hardware. In: NMR Methods for the Investigation of Structure and Transport. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21628-2_3
Download citation
DOI: https://doi.org/10.1007/978-3-642-21628-2_3
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-21627-5
Online ISBN: 978-3-642-21628-2
eBook Packages: Chemistry and Materials ScienceChemistry and Material Science (R0)