Abstract
Fluoroscopic overlay images rendered from pre-operative volumetric data can provide additional guidance for physicians during catheter ablation procedures for treatment of atrial fibrillation (AFib). As these overlay images are compromised by cardiac and respiratory motion, motion compensation methods have been proposed. The approaches so far either require simultaneous biplane imaging for 3-D motion compensation or, in case of mono-plane X-ray imaging, provide only a limited 2-D functionality. To overcome the downsides of the previously suggested methods, we propose a new approach that facilitates full 3-D motion compensation even if only mono-plane X-ray views are available. To this end, we use constrained model-based 2-D/3-D registration to track a circumferential mapping catheter which is commonly used during AFib catheter ablation procedures. Our approach yields an average 2-D tracking error of 0.6 mm and an average 3-D tracking error of 2.1 mm.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Gage, B., Waterman, A., Shannon, W., Boechler, M., Rich, M., Radford, M.: Validation of Clinical Classification Schemes for Predicting Stroke. JAMA 285(22), 2864–2870 (2001)
Haissaguerre, M., Gencel, L., Fischer, B., Le Metayer, P., Poquet, F., Marcus, F., Clementy, J.: Successful Catheter Ablation of Atrial Fibrillation. J. Cardiovasc Electrophysiol. 5, 1045–1052 (1994)
Calkins, H., Brugada, J., Packer, D., Cappato, R., Chen, S., Crijns, H., Damiano, R., Davies, D., Haines, D., Haissaguerre, M., Iesaka, Y., Jackman, W., Jais, P., Kottkamp, H., Kuck, K., Lindsay, B., Marchlinski, F., McCarthy, P., Mont, J., Moradi, F., Nademanee, K., Natale, A., Pappone, C., Prystowsky, E., Raviele, A., Ruskin, J., Shemin, R.: HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up. Europace 9(6), 335–379 (2007)
Prümmer, M., Wigström, L., Hornegger, J., Boese, J., Lauritsch, G., Strobel, N., Fahrig, R.: Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP. In: IEEE Nuclear Science Symposium Conference Record (2006)
Wittkampf, F., Wever, E., Derksen, R., Wilde, A., Ramanna, H., Hauer, R., Robles de Medina, E.: LocaLisa - New Technique for Real-Time 3-Dimensional Localization of Regular Intracardiac Electrodes. Circulation 99(13), 1312–1317 (1999)
Kistler, P., Rajappan, K., Jahngir, M., Earley, M., Harris, S., Abrams, D., Gupta, D., Liew, R., Ellis, S., Sporton, S., Schilling, R.: The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology 17(10), 1093–1101 (2006)
Kistler, P.M., Earley, M.J., Harris, S., Abrams, D., Ellis, S., Sporton, S.C., Schilling, R.J.: Validation of Three-Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology 17(4), 341–348 (2006)
Kistler, P.M., Rajappan, K., Harris, S., Earley, M.J., Richmond, L., Sporton, S.C., Schilling, R.J.: The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study. European Heart Journal 29(24), 3029–3036 (2008)
Daccarett, M., Segerson, N., Günther, J., Nölker, G., Gutleben, K., Brachmann, J., Marrouche, N.: Blinded correlation study of three-dimensional electro-anatomical image integration and phased array intra-cardiac echocardiography for left atrial mapping. Europace 9, 923–926 (2007)
Ector, J., De Buck, S., Huybrechts, W., Nuyens, D., Dymarkowski, S., Bogaert, J., Maes, F., Heidbüchel, H.: Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: Accuracy and clinical value. Heart Rhythm 5(7), 957–964 (2008)
Sra, J., Narayan, G., Krum, D., Malloy, A., Cooley, R., Bhatia, A., Dhala, A., Blanck, Z., Nangia, V., Akhtar, M.: Computed Tomography-Fluoroscopy Image Integration-Guided Catheter Ablation of Atrial Fibrillation. J. Cardiovasc Electrophysiol. 18(4), 409–414 (2007)
De Buck, S., Maes, F., Ector, J., Bogaert, J., Dymarkowski, S., Heidbüchel, H., Suetens, P.: An Augmented Reality System for Patient-Specific Guidance of Cardiac Catheter Ablation Procedures. IEEE Transactions on Medical Imaging 24(11), 1512–1524 (2005)
Brost, A., Liao, R., Hornegger, J., Strobel, N.: 3-D respiratory motion compensation during EP procedures by image-based 3-D lasso catheter model generation and tracking. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009. LNCS, vol. 5761, pp. 394–401. Springer, Heidelberg (2009)
Brost, A., Wimmer, A., Liao, R., Hornegger, J., Strobel, N.: Catheter tracking: Filter-based vs. Learning-based. In: Goesele, M., Roth, S., Kuijper, A., Schiele, B., Schindler, K. (eds.) Pattern Recognition. LNCS, vol. 6376, pp. 293–302. Springer, Heidelberg (2010)
Brost, A., Liao, R., Hornegger, J., Strobel, N.: Model-based registration for motion compensation during EP ablation procedures. In: Fischer, B., Dawant, B.M., Lorenz, C. (eds.) WBIR 2010. LNCS, vol. 6204, pp. 234–245. Springer, Heidelberg (2010)
Brost, A., Liao, R., Strobel, N., Hornegger, J.: Respiratory motion compensation by model-based catheter tracking during EP procedures. Medical Image Analysis 14(5), 695–706 (2010); Special Issue on the 12th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI) 2009
Quan, L.: Conic Reconstruction and Correspondence From Two Views. IEEE Trans. Pattern Anal. Mach. Intell. 18(2), 151–160 (1996)
Cychosz, J.: Efficient Binary Image Thinning using Neighborhood Maps. Graphics Gems IV, 465–473 (1994)
Breu, H., Gil, J., Kirkpatrick, D., Werman, M.: Linear time Euclidean distance transform algorithms. IEEE Trans. Pattern Anal. Mach. Intell. 17, 529–533 (1995)
Viola, P., Jones, M.: Robust real-time face detection. Int. J. Comput. Vision 57(2), 137–154 (2004)
Freund, Y., Schapire, R.: A decision-theoretic generalization of on-line learning and an application to boosting. JCSS 55(1), 119–139 (1997)
Breiman, L., Friedman, J., Olshen, R., Stone, C.: Classification and Regression Trees. Chapman & Hall, New York (1984)
Ector, J., De Buck, S., Loeckx, D., Coudyzer, W., Maes, F., Dymarkowski, S., Bogaert, J., Heidbüchel, H.: Changes in left atrial anatomy due to respiration: Impact on three-dimensional image integration during atrial fibrillation ablation. J. Cardiovasc Electrophysiol. 19(8), 828–834 (2008)
Gepstein, L., Hayam, G., Ben-Haim, S.: A Novel Method for Nonfluoroscopic Catheter-Based Electroanatomical Mapping of the Heart: In Vitro and In Vivo Accuracy Results. Circulation 95, 1611–1622 (1997)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Brost, A., Wimmer, A., Liao, R., Hornegger, J., Strobel, N. (2011). Constrained 2-D/3-D Registration for Motion Compensation in AFib Ablation Procedures. In: Taylor, R.H., Yang, GZ. (eds) Information Processing in Computer-Assisted Interventions. IPCAI 2011. Lecture Notes in Computer Science, vol 6689. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21504-9_13
Download citation
DOI: https://doi.org/10.1007/978-3-642-21504-9_13
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-21503-2
Online ISBN: 978-3-642-21504-9
eBook Packages: Computer ScienceComputer Science (R0)