Optimal left ventricular (LV) lead placement via the coronary sinus (CS) is a critical factor in defining response to cardiac resynchronization therapy (CRT). Using novel MR image acquisition, segmentation, overlay and registration software we set out to guide lead placement by avoiding scar and targeting the LV region with the latest mechanical activation. We previously reported clinical results for 7 patients and now present updated results. 17 patients underwent cardiac magnetic resonance (CMR) scans. 3D whole heart images were segmented to produce high-fidelity anatomical models of the cardiac chambers and coronary veins. Four-chamber and short-axis cine images were processed using Tomtec software to give a 16-segment time volume-dyssynchrony map. In patients with myocardial scar, the Gadolinium late enhancement images were manually segmented and registered to the anatomical model along with the dyssynchrony map. The 3 latest mechanically acti- vated segments with <50% scar were identified and this information was overlaid at CRT implant on to live X-ray fluoroscopic images using a prototype version of the Philips EP Navigator software (see figure). Subsequently, the X-ray C-arm and table could be moved freely whilst automatically maintaining a registered roadmap. We used a high-fidelity pressure wire to assess the acute haemodynamic response to pacing in different regions of the overlaid 16 segment model. 15 of the 17 patients underwent successful placement of a LV pacing lead via the CS with satisfactory pacing parameters and no phrenic nerve stimulation at implant. In 2 patients we were unable to place a LV lead successfully in any branch of the CS. We paced in at least one of our 3 target segments in 11 patients. 67% of patients were responders as defined by a 10% increase in +dP/dt over baseline. In conclusion, CMR-guided CRT allowed left lead placement in 15/17 patients with approximately 2/3 patients being acute responders. Furthermore, specific targeting was successful in 11/15 patients using the image-guidance system. Following this successful pilot study, we will commence a randomized control study to examine if image-guided implantation improves patient response to CRT.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Ma, Y. et al. (2011). Real-Time Cardiac MR Anatomy and Dyssynchrony Overlay for Guidance of Cardiac Resynchronization Therapy Procedures: Clinical Results Update. In: Metaxas, D.N., Axel, L. (eds) Functional Imaging and Modeling of the Heart. FIMH 2011. Lecture Notes in Computer Science, vol 6666. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-21028-0_39

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-21028-0_39

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-21027-3

  • Online ISBN: 978-3-642-21028-0

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics