Skip to main content

Applying UHF PD On-site Monitoring to Large-Size Power Transformer and Pulses Analysis

  • Conference paper
Future Intelligent Information Systems

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 86))

  • 1949 Accesses

Abstract

The use of partial discharge (PD) on-site monitoring as an indicator of HV equipments insulation condition is well known. However, the existence of external interferences has greatly reduced the credibility of PD on-site measurement technology of HV equipments. This paper describes practical application of the UHF PD detection method on a new oil-immersed power transformer and to suppress interference, an internal UHF sensor (antenna) was designed and successfully installed to power transformers for its insulation condition assessment which can effectively avoid the frequency band of the external interferences. As the frequency band of this UHF sensor was 300~1500MHz, envelope detection technique was used to extract UHF signals excited from PD sources inside the transformer. The results of MATLAB simulations have shown that UHF PD signals can be effectively extracted by this method. Using the monitoring system established in this paper, plenty of external interferences pulses and UHF PD pulses were recorded and investigated, PD pulses with small amplitude can be effectively detected, which reveal that UHF PD measurements can effectively measure small level of discharges with good sensitivity.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Judd, M.D., Cleary, G.P., Bennoch, C.J.: Applying UHF partial discharge detection to power transformers. IEEE Power Eng. Rev. 22, 57–59 (2002)

    Article  Google Scholar 

  2. Pearson, J.S., Farish, O., et al.: Partial discharge diagnostics for gas insulated substations. IEEE Trans. Dielect. Elect. Insul. 2, 893–905 (1995)

    Article  Google Scholar 

  3. Judd, M.D., Farish, O., Pearson, J.S., Hampton, B.F.: Dielectric windows for UHF partial discharge detection. IEEE Trans. Dielect. Elect. Insul. 8, 953–958 (2001)

    Article  Google Scholar 

  4. Raja, K., Devaux, F., Lelaidier, S.: Recognition of discharge sources using UHF PD signatures. IEEE Elect. Insul. Mag. 18, 8–14 (2002)

    Article  Google Scholar 

  5. Wang, G.L., Hao, Y.P., Li, Y.M.: Study on the ultra-high-frequency sensors for PD detection in power transformer. In: Proc. of 2001 Int. Symp. on Elect. Insul. Mater., Himeji, pp. 793–796 (2001)

    Google Scholar 

  6. Gulski, E.: Digital Analysis of Partial Discharges. IEEE Trans. Dielec. Elect. Insul. 2, 822–837 (1995)

    Article  Google Scholar 

  7. Judd, M.D., Yang, L., Hunter, I.B.B.: Partial discharge monitoring for power transformers using UHF sensors Part 1: Sensors and signal interpretation. IEEE Elect. Insul. Mag. 21, 5–13 (2005)

    Google Scholar 

  8. Liu, M., Li, Z.: An Online UHF PD Monitoring System for Power Transformer and Its Applications. In: 2010 Asia-Pacific Power and Energy Engineering Conference (APPEEC), Cheng Du, pp. 373–376 (2010)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Chuanli, G., Yuan, W., Yeping, Y., Hailong, C. (2011). Applying UHF PD On-site Monitoring to Large-Size Power Transformer and Pulses Analysis. In: Zeng, D. (eds) Future Intelligent Information Systems. Lecture Notes in Electrical Engineering, vol 86. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-19706-2_62

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-19706-2_62

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-19705-5

  • Online ISBN: 978-3-642-19706-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics