Skip to main content

Retrieval Wear Analysis of Metal-on-Metal Hip Resurfacing Implants Revised Due to Pseudotumours

  • Chapter
  • First Online:
  • 1094 Accesses

Abstract

Pseudotumours (soft-tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have been associated with elevated serum and hip aspirate metal ion levels, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify in vivo wear of implants revised for pseudotumours (8) and a control group of implants (22) revised for other reasons of failure.

In comparison with the non-pseudotumour implant group, the pseudotumour implant group was associated with: (1) significantly higher median linear wear rate of the femoral component: 8.1 mm/year (range 2.75–25.4 mm/year) vs. 1.79 mm/year (range 0.82–4.15 mm/year), p  =  0.002; and (2) significantly higher median linear wear rate of the acetabular component: 7.36 mm/year (range 1.61–24.9 mm/year) vs. 1.28 mm/year (range 0.18–3.33 mm/year), p  =  0.001. Wear on the acetabular cup components in the pseudotumour group always involved the edge, indicating edge-loading of the bearing.

This study provides the first direct evidence that pseudotumour is associated with increased wear at the MoM articulation. Furthermore, edge-loading with the loss of fluid film lubrication may be an important wear generation mechanism in patients with pseudotumour.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. MacDonald, S.J., McCalden, R.W., Chess, D.G., Bourne, R.B., Rorabeck, C.H., Cleland, D., Leung, F.: Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin. Orthop. Relat. Res. 406, 282–296 (2003)

    Article  PubMed  Google Scholar 

  2. Sieber, H.P., Rieker, C.B., Kottig, P.: Analysis of 118 second-generation metal-on-metal retrieved hip implants. J. Bone Joint Surg. Br. 81(1), 46–50 (1999)

    Article  PubMed  CAS  Google Scholar 

  3. Shimmin, A., Beaule, P.E., Campbell, P.: Metal-on-metal hip resurfacing arthroplasty. J. Bone Joint Surg. Am. 90(3), 637–654 (2008)

    Article  PubMed  Google Scholar 

  4. National Joint Registry England and Wales Annual Report (2008)

    Google Scholar 

  5. Australian Orthopaedic Association National Joint Replacement Registry Annual Report (2008)

    Google Scholar 

  6. Pandit, H., Glyn-Jones, S., McLardy-Smith, P., Gundle, R., Whitwell, D., Gibbons, C.L., Ostlere, S., Athanasou, N., Gill, H.S., Murray, D.W.: Pseudotumours associated with metal-on-metal hip resurfacings. J. Bone Joint Surg. Br. 90(7), 847–851 (2008)

    PubMed  CAS  Google Scholar 

  7. Grammatopoulos, G., Pandit, H., Kwon, Y.M., Gundle, R., McLardy-Smith, P., Beard, D.J., Murray, D.W., Gill, H.S.: Hip resurfacings revised for inflammatory pseudotumours have a poor outcome. J. Bone Joint Surg. Br. 91(8), 1019–1024 (2009)

    Google Scholar 

  8. Pandit, H., Vlychou, M., Whitwell, D., Crook, D., Luqmani, R., Ostlere, S., Murray, D.W., Athanasou, N.A.: Necrotic granulomatous pseudotumours in bilateral resurfacing hip arthoplasties: evidence for a type IV immune response. Virchows Arch. 453(5), 529–534 (2008)

    Article  PubMed  CAS  Google Scholar 

  9. Campbell, P., Shimmin, A., Walter, L., Solomon, M.: Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing. J. Arthroplasty 23(7), 1080–1085 (2008)

    Article  PubMed  Google Scholar 

  10. Gruber, F.W., Bock, A., Trattnig, S., Lintner, F., Ritschl, P.: Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J. Arthroplasty 22(6), 923–927 (2007)

    Article  PubMed  Google Scholar 

  11. Boardman, D.R., Middleton, F.R., Kavanagh, T.G.: A benign psoas mass following metal-on-metal resurfacing of the hip. J. Bone Joint Surg. Br. 88(3), 402–404 (2006)

    PubMed  CAS  Google Scholar 

  12. Kwon, Y.M., Ostlere, S., McLardy-Smith, P., Gundle, R., Whitwell, D., Gibbons, C.L.M., Athanasou, N.A., Gill, H.S., Murray, D.W.: Metal ion levels in pseudotumours associated with metal-on-metal hip resurfacings. In: The 55th Orthopaedic Research Society Annual Meeting, Las Vegas, USA, (2009)

    Google Scholar 

  13. De Smet, K., De Haan, R., Calistri, A., Campbell, P.A., Ebramzadeh, E., Pattyn, C., Gill, H.S.: Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J. Bone Joint Surg. Am. 90(Suppl 4), 202–208 (2008)

    Article  PubMed  Google Scholar 

  14. Campbell, P., Beaule, P.E., Ebramzadeh, E., LeDuff, M., De Smet, K., Lu, Z., Amstutz, H.C.: The John Charnley Award: a study of implant failure in metal-on-metal surface arthroplasties. Clin. Orthop. Relat. Res. 453, 35–46 (2006)

    Article  PubMed  Google Scholar 

  15. De Haan, R., Pattyn, C., Gill, H.S., Murray, D.W., Campbell, P.A., De Smet, K.: Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J. Bone Joint Surg. Br. 90(10), 1291–1297 (2008)

    PubMed  Google Scholar 

  16. Hussain, A., Counsell, L., Kamali, A.: Clinical effects of edge loading on metal-on-metal hip resurfacings. British Hip Society, Manchester, United Kingdom (2009)

    Google Scholar 

  17. Altman, D.G.: Statistics in Practice. British Medical Association, London (1982)

    Google Scholar 

  18. Taylor, S., Manley, M.T., Sutton, K.: The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J. Arthroplasty 22(7 Suppl 3), 47–51 (2007)

    Article  PubMed  Google Scholar 

  19. Jacobs, J.J., Gilbert, J.L., Urban, R.M.: Corrosion of metal orthopaedic implants. J. Bone Joint Surg. Am. 80(2), 268–282 (1998)

    PubMed  CAS  Google Scholar 

  20. Witzleb, W.-C., Guenther, K., Hanisch, U., Ziegler, J., Guenther, K.-P.: In vivo wear rate of the Birmingham Hip Resurfacing arthroplasty. J. Arthroplasty 24(6), 951–956 (2009)

    Article  PubMed  Google Scholar 

  21. De Haan, R., Pattyn, C., Gill, H.S., Murray, D.W., Campbell, P.A., De Smet, K.: Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J. Bone Joint Surg. Br. 90(10), 1291–1297 (2008)

    PubMed  Google Scholar 

  22. Udofia, I.J., Jin, Z.M.: Elastohydrodynamic lubrication analysis of metal-on-metal hip-­resurfacing prostheses. J. Biomech. 36(4), 537–544 (2003)

    Article  PubMed  CAS  Google Scholar 

  23. Liu, F., Jin, Z., Roberts, P., Grigoris, P.: Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. Proc. Inst. Mech. Eng., H: J. Eng. Med. 220(6), 695–704 (2006)

    Article  Google Scholar 

  24. Langton, D.J., Jameson, S.S., Joyce, T.J., Webb, J., Nargol, A.V.: The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J. Bone Joint Surg. Br. 90(9), 1143–1151 (2008)

    PubMed  CAS  Google Scholar 

  25. Dowson, D., Hardaker, C., Flett, M., Isaac, G.H.: A hip joint simulator study of the performance of metal-on-metal joints: part I: the role of materials. J. Arthroplasty 19(Suppl 8), 118–123 (2004)

    PubMed  Google Scholar 

  26. Back, D.L., Young, D.A., Shimmin, A.J.: How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin. Orthop. Relat. Res. 438, 177–181 (2005)

    Article  PubMed  Google Scholar 

  27. Chan, F.W., Bobyn, J.D., Medley, J.B., Krygier, J.J., Tanzer, M.: The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin. Orthop. Relat. Res. 369, 10–24 (1999)

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Young-Min Kwon .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Berlin Heidelberg

About this chapter

Cite this chapter

Kwon, YM., Gill, H.S., Murray, D.W., Kamali, A. (2011). Retrieval Wear Analysis of Metal-on-Metal Hip Resurfacing Implants Revised Due to Pseudotumours. In: Knahr, K. (eds) Tribology in Total Hip Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-19429-0_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-19429-0_11

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-19428-3

  • Online ISBN: 978-3-642-19429-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics