Zusammenfassung
Der Gleichgewichtszustand bei der SE-, FE- und FFE-Bildgebung stellt sich durch die strikte Einhaltung der Periodizität in der betreffenden Sequenz ein. Allen gemeinsam ist, dass in diesem Fall die ersten Anregungen der Sequenz für die Einstellung eines Gleichgewichtszustandes und nicht zur Datenakquisition dienen.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Literaturverzeichnis
Advances in cardiac application in sub-second FLASH MRI, D. Chien, K.-D. Merbold, W. Hanecke, H. Bruhn, M.L. Gyngell, J. Frahm, Magn. Res. Im. 8, p. 829, 1990
MR Mammography, W. Kaiser, Medica Mundi 36(2), p. 168, 1991
Snapshot FLASH MRI applications to T 1, T 2 and chemical shift imaging, A. Haase, Magn. Res. in Med. 13, p. 77, 1990
Approach to Equilibrium in Snapshot Imaging, R.A. Jonoe, P.A. Rinck, Magn. Res. Im. 8, p. 797, 1990
Signal Strength in Sub-second FLASH MRI Sequences, The Dynamic Approach to Steady State, W. Hanecke, K.-D. Merbold, D. Chien, M.L. Gyngell, H. Bruhm, J. Frahm, Abstracts SMRM, 1990, p. 458
Variable Flip Angle Snapshot GRASS Imaging, A.E. Holsinger, S.J. Riederer Abstracts SMRM, 1990, p. 453
Optimized (incremented) RF angle Gradient Echo imaging, M.K. Stehling Abstracts SMRM, 1990, p. 459
Rapid Three Dimensional T 1 Weighted MR, Imaging with the MP-Rage Sequence, J.P. Muggler, J.R. Brookman, Magn. Res. Im. 1, p. 561, 1991
T 2 weighted Three Dimensional MP-Rage Imaging, J.P. Muggler, T.A. Spraggins, J.R. Brookman, J. Magn. Res. Im. 1, p. 731, 1991
DPSF: Snapshot Flash Diffusion/Perfusion imaging, W.H. Perman, M. Gado, J.C. Sandstrorm, Abstracts SMRM, 1990, p. 309
Imaging of Diffusion and Micro-Circulation with Gradient Sensitization: Design; Strategy and Significance, D. le Bihan, R. Turner, C.T.W. Moonen, J.I. Pekar, J. Magn. Res. Im. 1, p. 7, 1991
Excitation Angle Optimization for Snapshot FLASH and a Signal Comparison with EPI, D.G. Norrie, J. Magn. Res. 91, p. 190, 1991
The Importance of Phase-Encoding Order in Ultra-Short TR Snapshot imaging, A.E. Holsinger, S.J. Riederer, J. Magn. Res. Im. 16, p. 481, 1990
Strategies to Improve Contrast in TurboFLash Imaging: Reordered Phase Encoding and K-Space Segmentation, D. Chien, D.A. Atkinson, R.A. Edelman, J. Magn. Res. Im. 1, p. 63, 1991
Steady State preparation for Spoiled Gradient Echo Imaging, R.B. Busse, S.J. Riederer, Magn. Res in Med. 45, pp. 653–661, 2001
Magnetization Prepared True FISP Imaging, M. Deimling, O. Heid, Proc. 2nd Ann. Meeting ISMRM, San Fransisco, 1994, p. 495
Magnetization Preparation during the Steady State: Fat Saturated 3D True FISP, K. Scheffler, O. Heid, J. Hennig, Magn. Res. in Med. 45, pp. 1073–1080, 2001
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2004 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Vlaardingerbroek, M.T., den Boer, J.A. (2004). Nichtstationäre Gradientenecho-Bildgebung. In: Magnetresonanzbildgebung. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-18697-4_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-18697-4_6
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-62252-6
Online ISBN: 978-3-642-18697-4
eBook Packages: Springer Book Archive