Abstract
This chapter aimed at throwing light on the Sick Building Syndrome (SBS) in Libraries, and the extent to which it is influenced by the internal environment of libraries. This was conducted through a case study of the main library of Sultan Qaboos University (SQU), located in both the old and the new buildings. To achieve this objective, the study adopted a descriptive survey methodology for the collection and description of the data, as well as a case-study methodology applied to the library building of SQU. The most important findings of the chapter showed that both the old and the new buildings of the library suffer from SBS. Sinusitis, dryness of the throat, and eye-inflammations were some of the most prominent SBS problems which librarians of the SQU library suffer from in both buildings. The chapter concludes with the recommendation that it is essential to observe environmental dimensions when designing library buildings, taking into consideration the expected impact of SBS in library buildings on librarians. It is hoped that this chapter will contribute to the enrichment of the scarce Arab intellectual output concerning this topic.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
AlAreeni MA (1994) Professional Development of Workers in Libraries and Information Centers. Al Dar Al Masreya Al Libnaneya, Cairo, 395p.
AlMorshidi MAA (2004) The General District Library in Egypt: An Evaluation Study. Thesis. Helwan University, Helwan.
AlSareehi HA (2005) Library safety and information systems: A case study of King Abdel Aziz Library Jeddah. King Fahd Natl Lib Mag 8(1):112–154.
AlSareehi HA, Hambeeshi NK (2001) The electronic library building: A theoretical study of the influences and variables. King Fahd Natl Lib Mag 6(2):196–224.
Apter A, Bracker A, Hodgson M, Sidman J, Leung WY (1994) Epidemiology of the sick building syndrome. J Allergy Clin Immunol 94:277–288.
Au Yeung YN, Chow WK, Lam VYK (1991) Sick building syndrome – A case study. Build Environ 26(4):319–330.
Balanli A, Ozturk A, Vural SM, Kucukcan B (2007) University library building in turkey: A survey and a case study of yildiz technical university main library building. J Acad Librarian 33(6):714–718.
Bass B, Economou V, Lee CKK, Perks T, Smith SA, Yip Q (2003) The interaction between physical and social-psychological factors in indoor environmental health. Environ Monit Assess 85:199–219.
Cando (1999) Guess Where the Air Pollution is Worse? Toronto Public Health, Toronto, ON.
Eriksson NM, Stenberg BGT (2006) Baseline prevalence of symptoms related to indoor environment. Scand J Public Health 34:387–396.
Fantuzzi G, Aggazzotti G, Righi E, Cavazzuti L, Predieri G, Franceschelli A (1996) Indoor air quality in the university libraries of modena (Italy). Sci Total Environ 193(1):49–56.
Fisk WJ (2000) Estimates of potential nationwide productivity and health benefits from better indoor environments: An update. In: Spengler JD, Samet JM, McCarthy JF (Eds.) Indoor Air Quality Handbook. McGraw-Hill, New York, NY.
Godish T, Spengler JD (1996) Relationships between ventilation and indoor air quality: A review. Indoor Air 6:135–145.
Hassan NM (2005) The digital revolution and library buildings: Activities and design (Central Library, University of King Saud, Riyadh-A Case Study). Sixth International Architecture Conference: The Digital Revolution and its Effect on Architecture and Construction, pp. 79–93.
Library of Congress (1991) Indoor air quality and work-environment study: Madison building, vol. 3. Association between health and comfort concerns and environmental conditions.
Morris A, Dennison P (1995) Sick building syndrome: Survey findings of libraries in great britain. Lib Manage 16(3):34–42.
Niemelä R, Seppänen O, Korhonen P, Reijula K (2006) Prevalence of building-related symptoms as an indicator of health and productivity. Am J Ind Med 49:819–825.
Niso (2001) Environmental conditions for exhibiting library and archival materials. ANSI/NISO Z39.79-2001, ISSN: 1041–5653.
Norbäck D, Nordström K (2008) Sick building syndrome in related to air exchange rate, CO2, room temperature and relative air humidity in university computer classrooms: An experimental study. Int Arch Environ Health 82:21–30.
Pereira GJF (2004) Outline of a methodology for construction of a healthy building. Revista Portuguesa De Pneumologia 10(3):227–233.
Raw GJ (1994) Sick Building: A Review of the Evidence on Cause and Solutions. Building Research Establishment, Watford.
Reinikainen LM, Jaakkola JJK (2001) Effects of temperature and humidification in the office environment. Arch Environ Health 56:365–368.
Reinikainen LM, Jaakkola JJK, Heinonen OP (1991) The effect of air humidification on different symptoms in office workers: An epidemiological study. Environ Int 17:243–250.
Righi E, Aggazzotti G, Fantuzzi G, Ciccarese V, Predieri G (2002) Air quality and well-being perception in subjects attending university libraries in modena (Italy). Sci Total Environ 286:41–50.
Seppanen O (1999) Estimated cost of indoor climate in finish buildings. In: Indoor air 991999, Edinburgh, Construction Research Communications, pp. 13–18.
Spengler JD, Samet JM (2003) Indoor environments and health: Moving into the 21st century. Proc Healthy Build 1:127–135.
Wargocki P, Sundell J, Bischof W, Brundrett G, Fanger PO, Gyntelberg F, Hanssen SO, Harrison P, Pickering A, Seppänen O, Wouters P (2002) Ventilation and health in non-industrial indoor environments: Report from a european multidisciplinary scientific consensus meeting (euroven). Indoor Air 12(2):113–128.
WHO (2005) Housing: Sick Building Syndrome (Pamphlet No. 2). World Health Organization Regional Office for Europe, Copenhagen. http://www.emro.who.int/ceha/publication_Details.asp?ID=46. Accessed May 2010.
Wyon D (1992) Sick buildings and the experimental approach. Environ Technol 3:313–322.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Berlin Heidelberg
About this chapter
Cite this chapter
Abdul-Wahab, S.A., Salem, N.M.B. (2011). Is Your Library Building Sick? A Case Study from the Main Library of Sultan Qaboos University at Sultanate of Oman. In: Abdul-Wahab, S. (eds) Sick Building Syndrome. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-17919-8_12
Download citation
DOI: https://doi.org/10.1007/978-3-642-17919-8_12
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-17918-1
Online ISBN: 978-3-642-17919-8
eBook Packages: EngineeringEngineering (R0)