Abstract
Registration and fusion of real-time trans-esophageal (TEE) and live fluoroscopy images have potential to provide improved visualization during minimally invasive aortic valve replacement and other cardiac interventions. We present an approach for achieving this registration using 3D TEE pose estimation from single-perspective x-ray images, and assess the performance of both point-based and intensity-based tracking techniques. Simulated and experimental accuracy studies demonstrated tracking errors of under 0.58mm and 0.32°, and phantom trials resulted in a 3D US-to-fluoroscopy RMS registration error of 3.5mm.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Walther, T., Simon, P., et al.: Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 116(11 Suppl.), I240–I245 (2007)
Lichtenstein, S.V., Cheung, A., et al.: Transapical transcatheter aortic valve implantation in humans: initial clinical experience. Circulation 114(6), 591–596 (2006)
Jain, A., Gutierrez, L., Stanton, D.: 3D TEE Registration with X-Ray Fluoroscopy for Interventional Cardiac Applications. In: Ayache, N., Delingette, H., Sermesant, M. (eds.) FIMH 2009. LNCS, vol. 5528, pp. 321–329. Springer, Heidelberg (2009)
Moore, J.T., Wiles, A.D., Wedlake, C., et al.: Integration of trans-esophageal echocardiography with magnetic tracking technology for cardiac interventions. In: SPIE, vol. 7625, 7625Y (2010)
Habets, D.F., Holdsworth, D.W., et al.: Error analysis of marker-based object localization using a single-plane XRII. Med. Phys. 36(1), 190–200 (2009)
Hoffmann, K.R., Esthappan, J.: Determination of three-dimensional positions of known sparse objects from a single projection. Med. Phys. 24(4), 555–564 (1997)
Penney, G.P., et al.: A comparison of similarity measures for use in 2-D-3-D medical image registration. IEEE Trans. Med. Imaging 17(4), 586–595 (1998)
Yoo, T., Whitaker, R., et al.: Engineering and Algorithm Design for an Image Processing API: A Technical Report on ITK - The Insight Toolkit. In: Proc. of Medicine Meets Virtual Reality (2002)
Fahrig, R., Holdsworth, D.W., et al.: Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion. Med. Phys. 24(7), 1097–1106 (1997)
Selvik, G., et al.: A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy. Acta Radiol. Diagn (Stockh) 24(4), 343–352 (1983)
Gobbi, D.G., Comeau, R.M., Peters, T.M.: Utrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol. 1679, pp. 920–927. Springer, Heidelberg (1999)
Chen, T., Abolmaesumi, P., et al.: A real-time ultrasound calibration system with automatic accuracy control and incorporation of ultrasound section thickness. In: Proc. SPIE, vol. 6918, 6918A (2008)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Lang, P., Seslija, P., Habets, D.F., Chu, M.W.A., Holdsworth, D.W., Peters, T.M. (2010). Three-Dimensional Ultrasound Probe Pose Estimation from Single-Perspective X-Rays for Image-Guided Interventions. In: Liao, H., Edwards, P.J."., Pan, X., Fan, Y., Yang, GZ. (eds) Medical Imaging and Augmented Reality. MIAR 2010. Lecture Notes in Computer Science, vol 6326. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-15699-1_36
Download citation
DOI: https://doi.org/10.1007/978-3-642-15699-1_36
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-15698-4
Online ISBN: 978-3-642-15699-1
eBook Packages: Computer ScienceComputer Science (R0)