Abstract
Tagged magnetic resonance (MR) imaging is unique in its ability to noninvasively image the motion and deformation of the heart. However, it is difficult to identify and quantify structures of interest in the cardiac anatomy since the tags obscure the anatomy. In this paper, we present a novel and fully automated technique based on nonrigid image registration for the analysis of myocardial motion using both tagged and untagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both tagged and untagged images. No manual intervention is required to obtain the segmentation of the end-diastolic images. To estimate the motion within the myocardium, we register a sequence of images taken during systole to a set of reference images taken at end-diastole, maximizing a spatial weighted similarity measure between the images. We use short-axis and long-axis images of the heart as well as tagged and untagged images to estimate a fully four-dimensional motion field within the myocardium. We have evaluated the proposed approach on 8 patients both in terms of robustness, accuracy and consistency of the motion tracking. The proposed method is significantly more consistent than motion tracking on tagged MR images only.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bistoquet, A., Oshinski, J., Škrinjar, O.: Myocardial deformation recovery from cine MRI using a nearly incompressible biventricular model. Medical Image Analysis 12(1), 69–85 (2008)
Chandrashekara, R., Mohiaddin, R.H., Rueckert, D.: Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration. IEEE Transactions on Medical Imaging 23(10), 1245–1250 (2004)
Ledesma-Carbayo, M.J., Kybic, J., Desco, M., Santos, A., Suhling, M., Hunziker, P., Unser, M.: Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation. IEEE Transactions on Medical Imaging 24(9), 1113–1126 (2005)
Lingrand, D., Charnoz, A., Koulibaly, P.M., Darcourt, J., Montagnat, J.: Toward accurate segmentation of the LV myocardium and chamber for volumes estimation in gated SPECT sequences. In: Pajdla, T., Matas, J(G.) (eds.) ECCV 2004. LNCS, vol. 3024, pp. 267–278. Springer, Heidelberg (2004)
Lorenzo-Valdés, M., Sanchez-Ortiz, G.I., Elkington, A.G., Mohiaddin, R.H., Rueckert, D.: Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm. Medical Image Analysis 8(3), 255–265 (2004)
Lynch, M., Ghita, O., Whelan, P.F.: Left-ventricle myocardium segmentation using a coupled level-set with a priori knowledge. Computerized Medical Imaging and Graphics 30(4), 255–262 (2006)
Mansi, T., Peyrat, J.M., Sermesant, M., Delingette, H., Blanc, J., Boudjemline, Y., Ayache, N.: Physically-Constrained Diffeomorphic Demons for the Estimation of 3D Myocardium Strain from Cine-MRI. In: Ayache, N., Delingette, H., Sermesant, M. (eds.) FIMH 2009. LNCS, vol. 5528, pp. 201–210. Springer, Heidelberg (2009)
Murgasova, M., Rueckert, D., Edwards, D., Hajnal, J.: Robust segmentation of brain structures in MRI. In: Proceedings of the Sixth IEEE International Conference on Symposium on Biomedical Imaging: From Nano to Macro, pp. 17–20. IEEE Press, Los Alamitos (2009)
Osman, N.F., Kerwin, W.S., McVeigh, E.R., Prince, J.L.: Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magnetic Resonance in Medicine 42(6), 1048 (1999)
Pan, L., Prince, J.L., Lima, J.A.C., Osman, N.F.: Fast tracking of cardiac motion using 3D-HARP. IEEE Transactions on Biomedical Engineering 52(8), 1425–1435 (2005)
Pavani, S.K., Delgado, D., Frangi, A.F.: Haar-like features with optimally weighted rectangles for rapid object detection. Pattern Recognition 43(1), 160–172 (2009)
Qian, Z., Huang, R., Metaxas, D., Axel, L.: A novel tag removal technique for tagged cardiac MRI and its applications. In: IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Citeseer, pp. 364–367 (2007)
Rueckert, D., Frangi, A.F., Schnabel, J.A.: Automatic construction of 3D statistical deformation models using non-rigid registration. In: Niessen, W.J., Viergever, M.A. (eds.) MICCAI 2001. LNCS, vol. 2208, pp. 77–84. Springer, Heidelberg (2001)
Rueckert, D., Sonoda, L.I., Hayes, C., Hill, D.L.G., Leach, M.O., Hawkes, D.J.: Nonrigid registration using free-form deformations: application to breast MR images. IEEE Transactions on Medical Imaging 18(8), 712–721 (1999)
Viola, P., Jones, M.: Robust real-time object detection. International Journal of Computer Vision 57(2), 137–154 (2002)
Young, A.A.: Model tags: direct three-dimensional tracking of heart wall motion from tagged magnetic resonance images. Medical Image Analysis 3(4), 361–372 (1999)
Zerhouni, E.A., Parish, D.M., Rogers, W.J., Yang, A., Shapiro, E.P.: Human heart: tagging with MR imaging–a method for noninvasive assessment of myocardial motion. Radiology 169(1), 59 (1988)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Shi, W., Murgasova, M., Edwards, P., Rueckert, D. (2010). Simultaneous Reconstruction of 4-D Myocardial Motion from Both Tagged and Untagged MR Images Using Nonrigid Image Registration. In: Liao, H., Edwards, P.J."., Pan, X., Fan, Y., Yang, GZ. (eds) Medical Imaging and Augmented Reality. MIAR 2010. Lecture Notes in Computer Science, vol 6326. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-15699-1_11
Download citation
DOI: https://doi.org/10.1007/978-3-642-15699-1_11
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-15698-4
Online ISBN: 978-3-642-15699-1
eBook Packages: Computer ScienceComputer Science (R0)