Abstract
Registration of MR volumes to X-ray mammograms is a clinically valuable task, as each modality provides complementary information on normal and abnormal breast tissue structure and function. We propose an intensity-based technique with a 3D volume-preserving affine transformation. An important part of our framework is the use of an Expectation-Maximization (EM) algorithm, with a Markov Random Field (MRF) regularization, that is used for breast tissue classification and subsequently the mapping of the MR intensities to X-ray attenuation. Initially, the proposed framework was tested on simulated X-ray data, where the goal was to register the original undeformed MRI to a simulated X-ray that was produced using a real compression image, acquired from volunteers in the MR scanner (8 cases). Since the ground truth in this case can be estimated from individually defined landmarks, we have evaluated the mean reprojection error, which was 3.83mm. The algorithm was then applied and evaluated visually on 5 cases that had both X-ray mammograms and MRIs.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Behrenbruch, C., Marias, K., Armitage, P., Moore, N., English, R., Clarke, J., Brady, M.: Fusion of contrast-enhanced breast MR and mammographic imaging data. Medical Image Analysis 7, 311–340 (2003)
Marti, R., Zwiggelaar, R., Rubin, C., Denton, E.: 2D-3D correspondence in mammography. Cybernetics and Systems 35, 85–105 (2004)
Ruiter, N., Stotzka, R., Muller, T., Gemmeke, H., Reichenbach, J., Kaiser, W.: Model-Based registration of X-ray Mammograms and MR images of the female breast. IEEE Transactions on Nuclear Science 53, 204–211 (2006)
Van Leemput, K., Maes, F., Vandermeulen, D., Suetens, P.: Automated Model-Based Tissue Classification of MR Images of the Brain. IEEE Transactions on Medical Imaging 18, 897–908 (1999)
Mertzanidou, T., Hipwell, J., Tanner, C., Hawkes, D.: An intensity-based approach to X-ray mammography – MRI registration. SPIE Medical Imaging: Image Processing, 7623–106 (2010)
Hipwell, J., Tanner, C., Crum, W., Schnabel, J., Hawkes, D.: A New Validation Method for X-ray Mammogram Registration Algorithms Using a Projection Model of Breast X-ray Compression. IEEE Transactions on Medical Imaging 26, 1190–1200 (2007)
Penney, G., Weese, J., Little, J., Desmedt, P., Hill, D., Hawkes, D.: A Comparison of Similarity Measures for Use in 2-D–3-D Medical Image Registration. IEEE Transactions on Medical Imaging 17, 586–595 (1998)
Hipwell, J., Penney, G., McLaughlin, R., Rhode, K., Summers, P., Cox, T., Byrne, J., Noble, A., Hawkes, D.: Intensity-based 2D–3D registration of celcelebral angiograms. IEEE Transactions on Medical Imaging 22, 1417–1426 (2003)
Wei, J., Chan, H., Helvie, M., Roubidoux, M., Sahiner, B., Hadjiiski, L., Zhou, C., Paquerault, S., Chenevert, T., Goodsitt, M.: Correlation between mammographic density and volumetric fibroglandular tissue estimated on breast MR images. Medical Physics 31, 933–942 (2004)
Nie, K., Chen, J., Chan, S., Chau, M., Yu, H., Bahri, S., Tseng, T., Nalcioglu, O., Su, M.: Development of a quantitative method for analysis of breast density based on three-dimensional breast MRI. Medical Physics 35, 5253–5262 (2008)
Tanner, C., White, M., Guarino, S., Hall-Craggs, M., Douek, M., Hawkes, D.: Anisotropic behaviour of breast tissue for large compressions. In: Proceedings of the IEEE International Symposium on Biomedical Imaging, pp. 1223–1226 (2009)
Leach, M., Boggis, C., Dixon, A., Easton, D., Eeles, R., Evans, D., Gilbert, F., Griebsch, I., Hoff, R., Kessar, P., Lakhani, S., Moss, S., Nerurkar, A., Padhani, A., Pointon, L., Thompson, D., Warren, R.: Screening with magnetic resonance imaging and mammography of a UK population at high familial risk of breast cancer: a prospective multicentre cohort study (MARIBS). The Lancet 365, 1769–1778 (2005)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Mertzanidou, T., Hipwell, J.H., Cardoso, M.J., Tanner, C., Ourselin, S., Hawkes, D.J. (2010). X-ray Mammography – MRI Registration Using a Volume-Preserving Affine Transformation and an EM-MRF for Breast Tissue Classification. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_4
Download citation
DOI: https://doi.org/10.1007/978-3-642-13666-5_4
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13665-8
Online ISBN: 978-3-642-13666-5
eBook Packages: Computer ScienceComputer Science (R0)