Performance Assessment of Breast Tomosynthesis Systems: Concepts for Two Types of Phantoms

  • Conference paper
  • 1449 Accesses

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 6136))

Abstract

In order to justify the clinical use of a new modality such as digital breast tomosynthesis (DBT), a performance test in terms of a clinical parameter is indicated. For screening applications, lesion detectability is crucial. Whereas a real phantom with typically a homogeneous background that includes a series of details may provide a good indication of such detectability, a more specific approach is needed if the potential advantages of DBT have to be assessed. More specifically, the potential of the reduction of soft tissue superposition has to be covered in the performance test. We propose 2 concepts for a performance evaluation phantom: a hardware phantom with lesion-like inserts and where a background can be simulated on top of the images, and a software phantom with simulated lesions of different size and density (that can originate from theoretical models or from attenuation templates of real lesions). We discuss the need and the use of these phantoms for performance testing.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Niklason, L.T., Christian, B.T., Niklason, L.E., Kopans, D.B., Castleberry, D.E., Opsahl-Ong, B.H., Landberg, C.E., Slanetz, P.J., Giardino, A.A., Moore, R., Albagli, D., DeJule, M.C., Fitzgerald, P.F., Fobare, D.F., Giambattista, B.W., Kwasnick, R.F., Liu, J., Lubowski, S.J., Possin, G.E., Richotte, J.F., Wei, C.Y., Wirth, R.F.: Digital Tomosynthesis in Breast Imaging. Radiology 205, 399–406 (1997)

    Google Scholar 

  2. Burgess, A.E., Jacobson, F.L., Judy, P.F.: Human observer detection experiments with mammograms and power-law noise. Med. Phys. 28, 419–437 (2001)

    Article  Google Scholar 

  3. EC (European Commission) 2006 European guidelines for quality assurance in breast cancer screening and diagnosis, 4th edn. European Commission, Brussels (2006)

    Google Scholar 

  4. Mertelmeier, T., Orman, J., Haerer, W., Dudam, M.K.: Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device. In: Medical Imaging 2006: Physics of Medical Imaging, Proceedings of SPIE, vol. 6142, pp. 61420F-1–61420F-12 (2006)

    Google Scholar 

  5. Bakic, P.R., Albert, M., Brzakovic, D., Maidment, A.D.A.: Mammogram synthesis using a 3D simulation I. Breast tissue model and image acquisition simulation. Med. Phys. 29, 2131–2139 (2002)

    Article  Google Scholar 

  6. Bliznakova, K., Bliznakov, Z., Bravou, V., Kolitsi, Z., Pallikarakis, N.: A three-dimensional breast software phantom for mammography simulation. Phys. Med. Biol. 48, 3699–3719 (2003)

    Article  Google Scholar 

  7. Smans, K., Carton, A.K., Zoetelief, J., Verbrugge, B., Haek, W., Struelens, L., Vanhavere, F., Bosmans, H.: Med. Phys. Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX. Accepted for publication in Med. Phys

    Google Scholar 

  8. Tward, D.J., Siewerdsen, J.H.: Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT. Med. Phys. 35, 5510–5529 (2008)

    Article  Google Scholar 

  9. Shaheen, E., Van Ongeval, C., Cockmartin, L., Zanca, F., Marshall, N., Jacobs, J., Bosmans, H.: Realistic Simulation of Microcalcifications in Breast Tomosynthesis. In: IWDM (2010)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bosmans, H. et al. (2010). Performance Assessment of Breast Tomosynthesis Systems: Concepts for Two Types of Phantoms. In: Martí, J., Oliver, A., Freixenet, J., Martí, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_31

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13666-5_31

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13665-8

  • Online ISBN: 978-3-642-13666-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics