Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/3))

  • 891 Accesses

Abstract

In this work we estimated the doses related to the Computer Tomography (CT) for the most frequent clinical examination protocols at the Radiology Department of the Oncology Institute of Coimbra. The dose evaluation methodology followed the European Guidelines. We determined Diagnostic Reference Levels (DRL) in terms of one slice, (Volume) Weighted Computed Tomography Dose Index - (CTDIvol) CTDIw, and in terms of complete exam, Dose Length Product - DLP for 3 CT scanners: Siemens Somaton Plus 4, GE HiSpeed LX/i and Siemens Somaton Sensation Open. The results were compared with the European Reference Levels EUR 16262 and with MSCT Bongartz (2004). A sample of 225 adult patients, both male and female, of standard size was selected, with a minimum of 10 patients for each clinical protocol and CT scanner. Local DRL’s were assigned as the average of the results for the 3 CT scanners. In general, DRL results are below the European reference levels for all protocols except thoracic, lumbar and sacrum spine. Additionally, effective doses were determined with the ImPACT’s CT dosimetry spreadsheet and were compared with those published in ICRP 102. To give more accessible information to the patient and physician, we converted the effective doses in terms of background equivalent radiation time (BERT) using the World average annual dose of 2.4 mSv/year.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Roda, A.R., Lopes, M.C., Fausto, A.M. (2009). Diagnostic Reference Levels in Computer Tomography at IPOCFG, EPE. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/3. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03902-7_9

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03902-7_9

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03901-0

  • Online ISBN: 978-3-642-03902-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics