Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/3))

Abstract

To keep radiation doses during computed tomography (CT) examinations as low as reasonably achievable, performing a detailed dose measurement is important. A flexible acrylic sheet roll CT dosimetry phantom (SRCT-P) with radiochromic film (RF) was developed to estimate in detail the dose distribution during pediatric CT examination. The SRCT-Ps were elliptically-shaped by rolling up flexible acrylic sheets (1.1 g/cm3). The dose distributions in the SRCT-P (body thickness and width: 6-8 cm [neonates], 10-12 cm [infants], and 14-16 cm [three-year-old children]) were evaluated. RFs were positioned from the center to the surface along the long- and short-axis directions in each SRCT-P. The scanning parameters of the single detector CT were 120 kV, 250 mA, 1.0 sec/rot, a slice thickness of 5 mm, and a 1.0 beam pitch. When the mean center dose at 10-12 cm on the SRCT-P was taken as 100%, the mean center doses at 6-8..or 14-16 cm were 145..or 43%, respectively, and the mean surface doses for 0, 90, and 180 degrees at 6-8, 10-12, and 14-16 cm of the SRCT-P were as follows: 158%, 159%, and 140%; 132%, 125%, and 116%; and 164%, 128%, and 131%, respectively. The center dose was increased with a decrease in the phantom size. The surface doses were decreased with decreasing phantom sizes of 14-16 to 10-12 cm; however, surface doses were increased with decreasing phantom sizes of 10-12 to 6-8 cm. The detail dose distribution of a CT examination can be measured separately by using a SRCT-P with a RF.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Gotanda, R., Katsuda, T., Gotanda, T., Tabuchi, A., Yatake, H., Takeda, Y. (2009). Dose Distribution in Pediatric CT Abdominal Examination: Phantom Study. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/3. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03902-7_14

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03902-7_14

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03901-0

  • Online ISBN: 978-3-642-03902-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics