The first national IMRT dosimetry inter comparison in Switzerland using a thorax phantom with inhomogeneities

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/1))

Abstract

In 2008, the first IMRT (intensity modulated radio therapy) dosimetry intercomparison of the SGSMP (Swiss Society of Radiobiology and Medical Physics) using a thorax phantom has been carried out. It was the aim to check the ability of the calculation algorithms used in practice to take into account inhomogeneities. Additionally, the feasibility of the selected procedure had to be tested. All 23 institutions performing radio-oncology in Switzerland participated in the intercomparison. Thereby 30 plan-measurement combinations have been used. The intercomparison results are presented here grouped by the applied calculation algorithms. Following Knöös et al. [1] and Fogliata-Cozzi et al. [2], the algorithms have been additionally classified as “type a” or ”type b”. As opposed to ”type a” algorithms, “type b” algorithms take into account the three dimensional density distribution and are able to treat the electron transport in an approximate way as well as the secondary photon transport. TLD (thermo luminescence dosimeter) and ionisation chamber measurements demonstrate that ”type b” algorithms generally show a better agreement between calculations and measurements. But there are still differences within the two groups of algorithms. The results demonstrate that the performed intercomparison is feasible and suggests that cancer patients in Switzerland get a suitable radiation therapy in any of the centers offering this treatment modality.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Schiefer, H., Nicolini, G., Fogliata, A., Seelentag, W.W., Fix, M.K. (2009). The first national IMRT dosimetry inter comparison in Switzerland using a thorax phantom with inhomogeneities. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03474-9_27

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03474-9_27

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03472-5

  • Online ISBN: 978-3-642-03474-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics