Minimally Penetrating Glaucoma Surgery with the Ex-PRESS™ Miniature Shunt

  • Chapter
Book cover Minimally Invasive Ophthalmic Surgery

Glaucoma is defined as a group of eye conditions that share either the common feature of progressive optic neuropathies (the open-angle variants) or the common feature of occludable drainage angles in the anterior chamber (the closed-angle variants). The primary goal of glaucoma therapy is to reduce IOP to the point where deterioration of the optic disk or visual fields ceases with a minimum of side effects or complications. The therapy currently available can be divided into three main groups: medical therapy, laser trabecu-loplasty, and filtering surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. GandolfiS, Traverso CF, Bron A et al (2002) Short-term results of a miniature draining implant for glaucoma in combined surgery with phacoemulsification. Acta Ophthalmol Scand Suppl 236:66

    Article  PubMed  CAS  Google Scholar 

  2. Garg SJ, Kanitkar K, Weichel E et al (2005) Trauma-induced extrusion of an Ex-PRESS™ glaucoma shunt presenting as an intraocular foreign body. Arch Ophthalmol 123:1270–1272

    Article  PubMed  Google Scholar 

  3. Kaplan-Messas A, Traverso C, Glovinsky Y et al (2001) The Ex-PRESS™ miniature glaucoma implant: intermediate results of a prospective multi-center study. Invest Ophthalmol Vis Sci 42: S55

    Google Scholar 

  4. Nyska A, Glovinsky Y, Belkin M et al (2003). Biocompatibility of the Ex-PRESS™ miniature glaucoma drainage implant. J Glaucoma 12:275–280

    Article  PubMed  Google Scholar 

  5. Stewart RM, Diamond JG, Ashmore ED et al (2005) Complications following Ex-PRESS™ glaucoma shunt implantation. Am J Ophthalmol 140:340–341

    PubMed  Google Scholar 

  6. Tavolato M, Babighian S, Galan A (2006) Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS™). Eur J Ophthalmol 16:753–755

    PubMed  CAS  Google Scholar 

  7. Traverso C, De Feo F, Messas-Kaplan A et al (2005) Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS™) in combined surgery with pha-coemulsification. Br J Ophthalmol 89:425–429

    Article  PubMed  CAS  Google Scholar 

  8. Verbraak FD, De Bruin DM, Sulak M et al (2005) Optical coherence tomography of the Ex-PRESS™ miniature glaucoma implant. Lasers Med Sci 20:41–44

    Article  PubMed  CAS  Google Scholar 

  9. Wamsley S, Moster MR., Rai S et al (2004) Results of the use of the Ex-PRESS™ miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmology 138:1049–1051

    Article  Google Scholar 

  10. Dahan E, Carmichael TR (2005) Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma 14:98–102

    Article  PubMed  Google Scholar 

  11. Mermoud A. Ex-PRESS™ implant — fast, simple, safe, effi-cient? Br J Ophthalmol 89:396–397

    Google Scholar 

  12. Schwartz KS, Richard K. et al (2006) Glaucoma drainage implants: a critical comparison of types. Curr Opin Ophthalmology 17:181–189

    Article  Google Scholar 

  13. De Jong LA (2005) Ex-PRESS™ positioned under a scleral flap, trabeculectomy and Ex-PRESS™ positioned under conjunctiva in patients with open angle glaucoma. A prospective comparison randomized 3-arms study. Invest Oph-thalmol Vis Sci 46:E-Abstract 68

    Google Scholar 

  14. Baudouin C, Pisella PJ, Fillacier K et al (1999) Ocular surface inflammatory changes induced by topical antiglaucoma drugs: human and animal studies. Ophthalmology 106:556–563

    Article  PubMed  CAS  Google Scholar 

  15. Broadway DC, Chang LP (2001) Trabeculectomy, risk factors for failure and the preoperative state of the conjunctiva. J Glaucoma 10:237–249

    Article  PubMed  CAS  Google Scholar 

  16. Broadway DC, Grierson I, O'Brien C et al (1994) Adverse effects of topical antiglaucoma medications I — the conjunc-tival cell profile. Arch Ophthalmol 112:1437–1445

    Article  PubMed  CAS  Google Scholar 

  17. Broadway DC, Grierson I, O'Brien C et al (1994) Adverse effects of topical antiglaucoma medications II – the outcome of filtration surgery. Arch Ophthalmol 112:1446–1454

    Article  PubMed  CAS  Google Scholar 

  18. Carmichael TR, Dahan E (2007) Functional filtration with minimal bleb formation using express miniature glaucoma device under a scleral flap. Invest Ophthalmol Vis Sci 48:E-Abstract 821

    Google Scholar 

  19. Coupin A, Li Q, Risse I (2007) Ex-PRESS™ miniature glaucoma implant inserted under a scleral flap in open glaucoma surgery: a retrospective study. J Fr Ophtalmologie 30:18–23

    Article  CAS  Google Scholar 

  20. Dahan E, Ben-Hur M (2006) Performance of two different versions of the Ex-PRESS™ mini-shunt under a scleral flap in open angle glaucoma patients. Invest Ophthalmol Vis Sci 47:E-Abstract 22

    Google Scholar 

  21. Dahan E, Carmichael TR (2005) The surgical treatment of neovascular glaucoma with a 200 micron miniature glaucoma shunt. Invest Ophthalmol Vis Sci 46:E-Abstract 77

    Google Scholar 

  22. De Feo F, Bagnis A, Bricola G et al (2006) Efficacy and safety of a stainless steel glaucoma drainage device implanted under a scleral flap. Invest Ophthalmol Vis Sci 47:E-Abstract 25

    Google Scholar 

  23. De Feo F, Papadia M, Bricola G et al (2005) Long term effi-cacy and safety of a stainless steel glaucoma drainage implant (Ex-PRESS™). Invest Ophthalmol Vis Sci 46: E-Abstract 72

    Google Scholar 

  24. De Feo F, Roccatagliata L, Bonzano L et al (2007) Artefacts of magnetic resonance imaging in patients implanted with a stainless steel glaucoma drainage micro-device. Invest Ophthalmol Vis Sci 48:E-Abstract 483

    Google Scholar 

  25. De Jong LA (2006) Ex-PRESS™ mini shunt under scleral flap compared to standard trabeculectomy. Invest Ophthalmol Vis Sci 47:E-Abstract 3544

    Google Scholar 

  26. Evangelista JA, Johnson DL, Trespalacios R et al (2006) Ex-PRESS™ shunt under a scleral flap for neovascular glaucoma. Invest Ophthalmol Vis Sci 47:E-Abstract 24

    Google Scholar 

  27. Johnson D, Bair C, Evangelista J et al (2006) Ex-PRESS™ shunt under a scleral flap as primary surgical treatment for open angle glaucomas. Invest Ophthalmol Vis Sci 47:E-Abstract 23

    Google Scholar 

  28. Lavin MJ, Worvald RFL, Migdal CS et al (1990) The influ-ence of prior therapy on the success of trabeculectomy. Arch Ophthalmol 108:1543–1548

    Article  PubMed  CAS  Google Scholar 

  29. Lopes JF, Moster MR, Wamsley S et al (2005) Ex-PRESS shunt implantation with scleral flap technique for complicated glaucoma. Invest Ophthalmol Vis Sci 46:E-Abstract 70

    Google Scholar 

  30. Maris PJ, Ishida K, Netland PK (2007) Comparison of trab-eculectomy with Ex-PRESS™ miniature glaucoma device implanted under a scleral flap. J Glaucoma 16:14–19

    Article  PubMed  Google Scholar 

  31. Maris PJ, Smith ME, Netland PA (2005) Clinical outcomes with the Ex-PRESS™ miniature glaucoma implant. Invest Ophthalmol Vis Sci 46:E-Abstract 71

    Google Scholar 

  32. Netland PA, Sarkisian SR Jr, Kanner EM et al (2007) Consecutive case series of the Ex-PRESS™ miniature glaucoma device implanted under a scleral flap. Invest Ophthalmol Vis Sci 48:E-Abstract 819

    Google Scholar 

  33. Pournaras JAC, Mermoud A (2007) Safety and efficacy of the new optonol microtube (DS Version) combined with modified deep sclerectomy in POAG patients: preliminary results. Invest Ophthalmol.Vis Sci 48:E-Abstract 818

    Google Scholar 

  34. Reis R, Lankaranian D, Ramos-Esteban JC et al (2006) Intermediate-term results of Ex-PRESS™ miniature glaucoma implant under scleral flap. Invest Ophthalmol Vis Sci 47:E-Abstract 50

    Google Scholar 

  35. Roy S, Bissig A, Broquet J et al (2007) Deep sclerectomy with the Ex-PRESS™ X-200 implant for the surgical treatment of refractory glaucomas. Invest Ophthalmol Vis Sci 48:E-Abstract 816

    Google Scholar 

  36. Sampson EM, Esson DW, Schultz GS et al. (2005) Expression of transforming growth factor β2 following sclerostomy and Ex-PRESS™ R50 glaucoma drainage implant under a scleral flap in a rabbit model. Invest Ophthalmol Vis Sci 46:E-Abstract 52

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Fine, I.H., Hoffman, R.S., Packer, M. (2010). Minimally Penetrating Glaucoma Surgery with the Ex-PRESS™ Miniature Shunt. In: Fine, I.H., Mojon, D.S. (eds) Minimally Invasive Ophthalmic Surgery. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-02602-7_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-02602-7_11

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-02601-0

  • Online ISBN: 978-3-642-02602-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics