Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 24))

Abstract

Using the new Continuous Loop Averaging Deconvolution (CLAD) acquisition technique, it is now possible to record evoked potentials at very high stimulation rates. The CLAD technique allows the experimenter to tailor the stimulation sequences to fit his specific application to unwrap overlapping responmses at high rates. CLAD sequences can be designed to reduce physiological adaptation effects and to control the noise shaping effect of the deconvolution process. This study shows examples of promising clinical applications of CLAD using Electrocochleograms (ECochGm), Auditory Brainstem Responses (ABR), Auditory Middle Latency Responses (AMLR): In the first example CLAD was applied to record TransTympanic (TT) ECochGm at conventional and high rates in Meniere’s patients. These high-rate ECochGs revealed distinctive physiological patterns not previously observed at conventional rates. Regarding the ABRs, custom CLAD sequences were designed to simultaneously provide high Signal to Noise Ratio (SNR) ABRs and 80-Hz Auditory Steady State Responses (ASSR). The use of these sequences enabled the investigators to assess the hearing in guinea pigs exposed to cochlear implant electrode insertion trauma. A similar technique was applied in normal human subjects to unveil the generation mechanisms of amplitude modulated ASSR. CLAD was also used to record 40-Hz MLRs in normal awake subjects and patients under anesthesia; the ASSR showed to be a composite of the evoked, transient waveforms. Thus CLAD was able to explain the inability of 5- or 10-Hz AMLRs to predict the 40-Hz ASSR in anesthesia.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bohórquez, J., Özdamar, Ö., McNeer, R., Morawski, K. (2009). Clinical Applications of Evoked Potential Continuous Loop Averaging Deconvolution (CLAD). In: McGoron, A.J., Li, CZ., Lin, WC. (eds) 25th Southern Biomedical Engineering Conference 2009, 15 – 17 May 2009, Miami, Florida, USA. IFMBE Proceedings, vol 24. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01697-4_47

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-01697-4_47

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-01696-7

  • Online ISBN: 978-3-642-01697-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics