- 1.
Paper suppliers prefer to specify the paper “thickness” in grams per square metres (g/m2).
- 2.
In older books on the subject, the word “sheathing” is used for “armouring”.
- 3.
Cables for submarine applications are explicitly excluded from the scope of IEC 60502-2. However, it can be considered to use IEC 60502-2 for informational tests in medium voltage submarine cables.
- 4.
4Electra No. 171 is “primarily meant for cables having a rated voltage U0 higher than 36 kV a.c. or 100 kV d.c.”. However, Electra 189a covering 33 kV cables refers to Electra 171.
- 5.
The established expression “side-wall pressure” actually does not denote a pressure (N/m2) in a classical sense but a force per unit length. The unit of SWP is kN/m.
References
Bartnikas R (Ed.) (2000). Power and Communication Cables, IEEE Press Series on Power Engineering, ISBN 0-7803-1196-5.
McAllister D (1982). Electric Cables Handbook. Granada Technical Books Ltd, 1982, ISBN 0-246-11467-3.
Goodwin F E et al. (1994). Recent Technological Developments for Lead Sheathed Cables. Transmission and Distribution Conference, 1994. Proceedings of the 1994 IEEE Power Engineering Society, 10–15 April 1994, pp. 568ff, Chicago, USA.
Worzyk T (1996). Keine Gefahr bei Lecks in HGÜ-Seekabeln. Elektrizitätswirtschaft, Vol. 26.
Wilkinson H D (1898). Submarine Cable Laying and Repairing, The Electrician Printing and Publishing Company, London.
Gilbertson O (2000). Electric Cables for Power and Signal Transmission, John Wiley & Sons, New York.
Recommendations for Tests of Power Transmission dc Cables for Rated Voltages up to 800 kV. Electra No. 189, April 2000, pp. 39ff.
Recommendations for Testing of Long ac Submarine Cables with Extruded Insulation for System Voltage above 30 (36) to 150 (170) kV. Electra No. 189, April 2000, pp. 29ff.
Cigré publication of Working group 21.01 (2003). Recommendations for Testing DC Extruded Cable Systems for Power Transmission at a Rated Voltage up to 250 kV. Cigré Technical Brochure 219, February 2003, Paris, France.
Bex S et al. (2006). Basslink HVDC Design Provisions Supporting Ac System Performance. Cigré session 2006, Paper B4-301.
Agrawal K C (2001). Industrial Power Engineering and Applications Handbook, Newnes, ISBN 0750673516, 9780750673518.
Hällström J and Bergman A et al. (2007). International Comparison of Software for Calculation of Lightning Impulse Parameters Based on a New Processing Algorithm. Proceedings of the XVth International Symposium on High Voltage Engineering, Paper T10-539.
Berlijn S et al. (1999). Today’s Problems with the Evaluation Methods of Full Lightning Impulse Parameters as Described in IEC 60060-1, 11th International Symposium on High Voltage Engineering, 1999. Conferences Publ. No. 467, Vol. 1, pp. 49–52.
Schufft W et al. (2000). Resonant Test System with Variable Frequency for On-site Testing and Diagnostics of Cables, HV Testing, Monitoring and Diagnostics Workshop, Alexandria, VA, USA, 13–14 September 2000.
Schikarski P et al. (1999). Two Years of Experience with a Mobile Resonant Test System for Testing of Installed Medium- and High Voltage Power Cables, International Symposium on High-Voltage Engineering, London, UK, August 1999.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Worzyk, T. (2009). Manufacturing and Testing. In: Submarine Power Cables. Power Systems. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-01270-9_5
Download citation
DOI: https://doi.org/10.1007/978-3-642-01270-9_5
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-01269-3
Online ISBN: 978-3-642-01270-9
eBook Packages: EngineeringEngineering (R0)