Abstract
Positron emission tomography (PET) is used for independent monitoring of dose delivery in ion therapy. An in-beam PET scanner registers the annihilation 7-rays following the decay of ß+-radioactive nuclei produced via nuclear reactions between the ions of the therapeutic beam and the irradiated tissue. From a comparison of the reconstructed activity distributions with those predicted from the treatment plan, deviations between the prescribed and the applied dose can be detected. In-beam PET, therefore, allows to verify the physical beam model of the treatment planning, to detect patient dislocations and density changes in the irradiated tissue. Issues related to the image quality and evaluation of a whole PET imaging system are discussed in this paper.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Enghardt W, Parodi K, Crespo P, et al. Dose quantification from in-beam positron emission tomography. Radiother Oncol. 2004;73:96–98.
Enghardt W, Crespo P, Fiedler F, et al. Charged hadron tumour therapy monitoring by means of PET. Nucl Instrum Methods Phys Res. 2004;525:284–288.
Fiedler F, Shakirin G, Crespo P, et al. On the efficiency of ion range determination from in-beam PET data. Radiother Oncol, submitted.
Pönisch F, Enghardt W, Lauckner K. Attenuation and scatter correction for in-beam positron emission tomography monitoring of tumour irradiations with heavy ions. Phys Med Biol. 2003;48:2419–2436.
Shakirin G, Crespo P, Enghardt W. A method for system matrix construction and processing for reconstruction of in-beam PET data. IEEE Trans Nucl Sci. 2007;54:1710–1716.
Crespo P, Shakirin G, Fiedler F, et al. Direct time-of-flight for quantitative, real-time in-beam PET: A concept and feasibility study. Phys. med. biol., 52: pp. 6795–6811, 2007. Phys Med Biol. 2007;52:6795–6811.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Shakirin, G., Fiedler, F., Enghardt, W. (2009). Evaluation Scheme for a Positron Emission Tomography System Used in Monitoring of Radiation Therapy. In: Meinzer, HP., Deserno, T.M., Handels, H., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2009. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-93860-6_30
Download citation
DOI: https://doi.org/10.1007/978-3-540-93860-6_30
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-93859-0
Online ISBN: 978-3-540-93860-6
eBook Packages: Computer Science and Engineering (German Language)