Abstract
Many patients still die every year as a result of anastomotic leakage after surgery. An objective aid to monitor the anastomotic site pre- and postoperatively and detect leakage at an early stage is needed. We propose a miniature measurement system to detect adequate tissue oxygenation pre- and postoperatively (continuously for 7 days) on the colon. The complete sensor chip should include an oxygen-tension sensor (pO2), a carbon dioxide tension sensor (pCO2) and a temperature sensor. The work presented here focuses on the measurements done with the oxygen-tension and temperature sensors. In-vitro measurements have been initially performed to test the sensor system and in-vivo tests were carried out on the kidney and the intestines of male wistar rats. The results obtained so far have shown the suitability of this technique for clinical application, therefore sensor-system miniaturisation is presently underway.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Kanellos, I., Vasiliadis, K., Angelopoulos, S., et al.: Anastomotic leakage following anterior resection for rectal cancer. Tech. Coloproctol. 8 (suppl. 1), s79–s81 (2004)
Guenaga, K.F., Matos, D., Castro, A.A., Atallah, A.N., Wille-Jorgensen, P.: Mechanical bowel preparation for elective colorectal surgery. Cochrane Database Syst. Rev. 2, CD001544 (2003)
Peeters, K.C., Tollenaar, R.A., Marijnen, C.A., et al.: Risk factors for anastomotic failure after total mesorectal excision of rectal cancer. British Journal of Surgery 92(2), 211–216 (2005)
Choi, H.-K., Lau, W.-L., Ho, J.W.C.: Leakage after resection and intraperitoneal anastomosis for colorectal malignancy: analysis of risk factors. Dis. Colon. Rectum 49, 1719–1725 (2006)
Eckmann, C., Kujath, P., Schiedeck, T.H., Shekarriz, H., Bruch, H.P.: Anastomotic leakage following low anterior resection: results of a standardized diagnostic and therapeutic approach. Int. J. Colorectal Dis. 19(2), 128–133 (2004)
Alves, A., Panis, Y., Pocard, M., Regimbeau, J.M., Valleur, P.: Management of anastomotic leakage after nondiverted large bowel resection. J. Am. Coll. Surg. 189(6), 554–559 (1999)
Hyman, N., Manchester, T.L., Osler, T., Burns, B., Cataldo, P.A.: Anastomotic leaks after intestinal anastomosis: it’s later than you think. Ann. Surg. 245(2), 254–258 (2007)
Macarthur, D.C., Nixon, S.J., Aitken, R.J.: Avoidable deaths still occur after large bowel surgery. British J. Surg. 85(1), 80–83 (1998)
Draaijer, A., Konig, J.W., Gans, O., Jetten, J., Douwma, A.C.: A novel optical method to determine oxygen in beer bottles. In: EMC Congress, France (1999)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Tanase, D. et al. (2008). Tissue-Viability Monitoring Using an Oxygen-Tension Sensor. In: Fred, A., Filipe, J., Gamboa, H. (eds) Biomedical Engineering Systems and Technologies. BIOSTEC 2008. Communications in Computer and Information Science, vol 25. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-92219-3_8
Download citation
DOI: https://doi.org/10.1007/978-3-540-92219-3_8
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-92218-6
Online ISBN: 978-3-540-92219-3
eBook Packages: Computer ScienceComputer Science (R0)