Computer-Aided Delivery of High-Intensity Focused Ultrasound (HIFU) for Creation of an Atrial Septal Defect in Vivo

  • Conference paper
Medical Imaging and Augmented Reality (MIAR 2008)

Abstract

In recent years, several fetal cardiac malformations have been increasingly treated before birth with gradually improved outcome, although the technique is still demanding and invasive. We newly developed a computer-aided system for energy delivery of high-intensity focused ultrasound (HIFU) to correct cardiac morphologic abnormalities in vivo much less invasively. The HIFU system could be controlled in real-time by a computer-based analysis of 2D-sonographic left ventricular images for optimal triggering off HIFU. Using beating heart of two anesthetized adult rabbits, the system successfully achieved a non-touch gross ablation of the atrial septum in one animal, and in the other HIFU energy was inadvertently mistargeted on the posterior wall of the left atrium with a resultant small transmural opening. We believe that the HIFU system will be introduced with pinpoint accuracy to minimally invasive treatment of fetal cardiac abnormalities that have intact or highly restrictive atrial septum.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Kohl, T., Sharland, G., Allan, L.D., Gembruch, U., Chaoui, R., Lopes, L.M., Zielinsky, P., Huhta, J., Silverman, N.H.: World experience of percutaneous ultrasound-guided balloon valvuloplasty in human fetuses with severe aortic valve obstruction. Am. J. Cardiol. 85, 1230–1233 (2000)

    Article  Google Scholar 

  2. Marshall, A.C., van der Velde, M.E., Tworetzky, W., Gomez, C.A., Wilkins-Haung, L., Benson, C.B., Jennings, R.W., Lock, J.E.: Creation of an atrial septal defect in utero for fetuses with hypoplastic left heart syndrome and intact or highly restrictive atrial septum. Circulation 110, 253–258 (2004)

    Article  Google Scholar 

  3. Makikallio, K., McElhinney, D.B., Levine, J.C., Marx, G.R., Colan, S.D., Marshall, A.C., Lock, J.E., Marcus, E.N., Tworetzky, W.: Fetal Aortic valve stenosis and the evolution of hypoplastic left heart syndrome patient selection for fetal intervention. Circulation 113, 1401–1405 (2006)

    Article  Google Scholar 

  4. Rebillard, X., Gelet, A., Davin, J.L., Soulie, M., Prapotnich, D., Cathelineau, X., Rozet, F., Vallancien, G.: Transrectal high-intensity focused ultrasound in the treatment of localized prostate cancer. J. Endourol. 19(6), 693–701 (2005)

    Article  Google Scholar 

  5. Chan, A.H., Fujimoto, V.Y., Moore, D.E., Martin, R.W., Vaezy, S.: An image-guided high intensity focused ultrasound device for uterine fibroids treatment. Med. Phys. 29(11), 2611 (2002)

    Article  Google Scholar 

  6. Hengst, S.A., Ehrenstein, T., Herzog, H., Beck, A., Utz-Billing, I., David, M., Felix, R., Ricke, J.: Magnetic resonance tomography guided focused ultrasound surgery (MRgFUS) in tumor therapy?anew noninvasive therapy option. Radiologe 44(4), 339–346 (2004)

    Article  Google Scholar 

  7. U.S. Department of Health and Human Services, Public Health Service, National Institutes of Health. Guide for the care and use of laboratory animals, pp. 85–23. NIH Publication (1985)

    Google Scholar 

  8. Otsuka, R., Fujikura, K., Hirata, K., Pulerwitz, T., Oe, Y., Suzuki, T., Sciacca, R., Marboe, C., Wang, J., Burkhoff, D., Muratore, R., Lizzi, F.L., Homma, S.: In vitro ablation of cardiac valves using high-intensity focused ultrasound. Ultrasound in Med. & Biol. 31(1), 109–114 (2005)

    Article  Google Scholar 

  9. Fujikura, K., Otsuka, R., Kalisz, A., Ketterling, J.A., Jin, Z., Sciacca, R.R., Marboe, C.C., Wang, J., Muratore, R., Feleppa, E.J., Homma, S.: Effects of ultrasonic exposure parameters on myocardial lesions induced by high-intensity focused ultrasound. J. Ultrasound Med. 25, 1375–1386 (2006)

    Google Scholar 

  10. Lee, L.A., Simon, C., Bove, L.E., Mosca, R.S., Ebbini, E.S., Abrams, G.D., Ludomirsky, A.: High intensity focused ultrasound effect on cardiac tissues: Potential for Clinical application. Echocardiography 17(6), 563–566 (2000)

    Article  Google Scholar 

  11. Xu, Z., Ludmirsky, A., Eun, L.Y., Hall, T.L., Tran, B.C., Fowlkes, J.B., Cain, C.A.: Controlled ultrasound tissue erosion. IEEE transactions on ultrasonics, ferroelectrics, and frequency control 51(6), 726–736 (2004)

    Article  Google Scholar 

  12. Kluiwstra, J.U.A., Tokano, T., Davis, J., Strickberger, S.A., Cain, C.A.: Real time image guided high intensity focused ultrasound for myocardial ablation: In Vivo study. In: IEEE Ultrasonics Symposium, vol. 1327 (2007)

    Google Scholar 

  13. Strickberger, S.A., Tokano, T., Kluiwstra, J.U.A., Morady, F., Cain, C.: Extracardiac ablation of the canine atrioventricular junction by use of high-intensity focused ultrasound. Circulation 100, 203–208 (1999)

    Google Scholar 

  14. Koizumi, N., Ota, K., Lee, D., Yoshizawa, S., Ito, A., Kaneko, Y., Yoshinaka, K., Matsumoto, Y., Mitsuishi, M.: Feed-forward controller for the integrated non-invasive ultrasound diagnosis and treatment. J. Robotics and Mechatronics 20(1), 89–97 (2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Takeyoshi Dohi Ichiro Sakuma Hongen Liao

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Yamashita, H. et al. (2008). Computer-Aided Delivery of High-Intensity Focused Ultrasound (HIFU) for Creation of an Atrial Septal Defect in Vivo. In: Dohi, T., Sakuma, I., Liao, H. (eds) Medical Imaging and Augmented Reality. MIAR 2008. Lecture Notes in Computer Science, vol 5128. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79982-5_33

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-79982-5_33

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-79981-8

  • Online ISBN: 978-3-540-79982-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics