Summary
In this chapter, we discuss the factors that affect image quality of DW-MRI and practical methods to improve the quality of DW-MR images obtained from clinical scanners. We demonstrate how simple phantoms may be used to improve image quality so that high-quality images can be attained consistently. We review the relative merits of fat-suppression schemes and how these may be applied to different clinical applications. We discuss the optimization of b-values and the number of b-values required for clinical imaging and further illustrate the range of considerations required for these choices. We survey the different data acquisition methods using breath-holding, physiological gating or free breathing, and how the choice of data acquisition method may relate to a particular scanning application. Finally, we provide recommendations to enable the reader to develop their own practical diffusion-weighted imaging protocols in the body.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Alexander AL, Tsuruda JS, Parker DL (1997) Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients. Magn Reson Med 38:1016–1021
Bammer R, Auer M, Keeling SL et al (2002) Diffusion tensor imaging using single-shot SENSE-EPI. Magn Reson Med 48:128–136
Bammer R, Keeling SL, Augustin M et al (2001) Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 46:548–554
Bito Y, Hirata S, Yamamoto E (1995) Optimum gradient factors for apparent diffusion coefficient measurements. Proc Intl Soc Mag Reson Med 913
Blackledge M, Wilton B, et al (2009). “Computed Diffusion Weighted Imaging (cDWI) for Improving Imaging Contrast.” Proc. Intl. Soc. Mag. Reson. Med.: 4005.
Blaimer M, Breuer F, Mueller M et al (2004) SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method. Top Magn Reson Imaging 15:223–236
Bodammer N, Kaufmann J, Kanowski M et al (2004) Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Magn Reson Med 51:188–193
Chen ZG, Li TQ, Hindmarsh T (2001) Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique. A methodological study of the aging brain. Acta Radiol 42:447–458
Gudbjartsson H, Patz S (1995) The Rician distribution of noisy MRI data. Reson Med 34:910–914
Jones DK, Horsfield MA, Simmons A (1999) Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med 42:515–525
Kingsley PB (2006a) Introduction to diffusion tensor imaging mathematics: part II. Anisotropy, diffusion-weighting factors, and gradient encoding schemes. Concepts Magn Reson A 28A:123–254.
Kingsley PB (2006b) Introduction to diffusion tensor imaging mathematics: part III. Tensor calculation, noise, simulations, and optimization. Concepts Magn Reson A 28A:155–179
Koch M, Norris DG (2000) An assessment of eddy current sensitivity and correction in single-shot diffusion-weighted imaging. Phys Med Biol 45:3821–3832
Kwee TC, Takahara T, Ochiai R et al (2008) Diffusion-weighted whole-body imaging with background body signal suppression (DW-MRIBS): features and potential applications in oncology. Eur Radiol 18:1937–1952
Larkman DJ, Nunes RG (2007) Parallel magnetic resonance imaging. Phys Med Biol 52:R15–R55
Le Bihan D, Poupon C, Amadon A et al (2006) Artifacts and pitfalls in diffusion MRI. J Magn Reson Imaging. 24:478–488
Li S, Sun F, Jin ZY et al (2007) Whole-body diffusion-weighted imaging: technical improvement and preliminary results. J Magn Reson Imaging 26:1139–1144
Marks M P, Olivot JM, Kemp S et al (2008) Patients with acute stroke treated with intravenous tPA 3–6 hours after stroke onset: correlations between MR angiography findings and perfusion- and diffusion-weighted imaging in the DEFUSE study. Radiology 249:614–623
Padhani AR, Liu G, Mu-Koh D et al (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11:102–125
Price WS (1998) Pulsed-field gradient NMR as a tool for studying translational diffusion. Part II: experimental aspects. Concepts Magn Reson 10:197–237
Pruessmann KP, Weiger M, Scheidegger MB et al (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962
Reese TG, Heid O, Weisskoff RM et al (2003) Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 49:177–182
Saritas EU, Lee JH, Nishimura DG (2007) Optimum b-value vs. SNR for apparent diffusion coefficient measurements. Proc Intl Soc Mag Reson Med 1508
Saritas EU, Lee JH, Nishimura DG (2008) Effects of T2 -weighting on optimum b-value vs. SNR for ADC measurements. Proc Intl Soc Mag Reson Med 1798
Stejskal EO, Tanner JE (1965) Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Chem Phys 42:288–292
Tofts PS, Lloyd D, Clark CA et al (2000) Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo. Magn Reson Med 43:368–374
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Collins, D.J., Blackledge, M. (2010). Techniques and Optimization. In: Koh, D.M., Thoeny, H.C. (eds) Diffusion-Weighted MR Imaging. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-78576-7_2
Download citation
DOI: https://doi.org/10.1007/978-3-540-78576-7_2
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-78575-0
Online ISBN: 978-3-540-78576-7
eBook Packages: MedicineMedicine (R0)