User’s Expertise Differences When Interacting with Simple Medical User Interfaces

  • Yuanhua Liu
  • Anna-Lisa Osvalder
  • MariAnne Karlsson
Part of the Lecture Notes in Computer Science book series (LNCS, volume 4799)

Abstract

In order to provide helpful proposals for future redesign of insulin pump interfaces, a study was carried out to investigate the expertise difference between novice users and expert users when interacting with a simple user interface of insulin pumps. In this study, two user groups with 13 participants in each, evaluated an insulin pump interface on a computer demo in usability tests. The results showed there was no significant difference between the novice users and expert users regarding the task completion time and the number of failures in performance. As for the cause of failures, the novice users showed weakness in domain knowledge, while the expert users showed weakness in task knowledge. No significant difference was shown on users’ satisfaction between the two user groups. The results also implied that the novice users elaborated their redesign suggestions in a deductive and summaric way, while the expert users proposed suggestions in an inductive and thorough way.

Keywords

Simple Medical User Interface Expertise differences Usability Test Novice User Expert User Insulin Pump 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Eriksson, M.: Insulin Pump with Integrated Continuous Glucose Monitoring - A Design Proposal with the User in Focus. Master Thesis. Department of Product and Production Development, Division of Design, Chalmers University of Technology, Gothenburg, Sweden (2006)Google Scholar
  2. 2.
    Bligård, L.-O., Jönsson, A., Osvalder, A.-L.: Utvärdering och konceptdesign av användargränssnitt för insulinpumpar. (in Swedish) Internal Report 19, Department of Product and Production Development, Division of Human Factors Engineering, Chalmers University of Technology, Gothenburg, Sweden (2003)Google Scholar
  3. 3.
    Bligård, L.-O., Jönsson, A., Osvalder, A.-L.: Eliciting User Requirements and evaluation of Usability for Insulin Pumps. In: NES. Proceedings of the Nordic Ergonomic Society’s 36th Annual Conference, Kolding, Denmark (2004)Google Scholar
  4. 4.
    Nielsen, J.: Usability Engineering. Academic Press, San Diego (1993)zbMATHGoogle Scholar
  5. 5.
    McClelland, I.: Product assessment and user trials. In: Wilson, J.R., Corlett, E.N. (eds.) Evaluation of Human Work, Taylor & Francis Ltd., London (1995)Google Scholar
  6. 6.
    Brooke, J.: SUS - A Quick and Dirty Usability Scale. In: Jordan, P.W., et al. (eds.) Usability Evaluation in Industry, Taylor & Francis Ltd., London (1996)Google Scholar
  7. 7.
    Neisser, U.: Cognition and Reality. Freeman, San Francisco (1976)Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2007

Authors and Affiliations

  • Yuanhua Liu
    • 1
  • Anna-Lisa Osvalder
    • 1
  • MariAnne Karlsson
    • 1
  1. 1.Chalmers University of Technology, 412 96 Gothenburg, Sweden, Department of Product and Production Development, Division Design 