Abstract
This work aims at investigating the somatosensory evoked potential topographical distribution by applying the Magnitude Squared Coherence (MSC), an Objective Response Detection technique in the frequency domain. The EEG was collected from eight volunteers at derivations according to the 10–20 International System during stimulation of the right posterior tibial nerve. The stimuli were applied at the rate of 5 Hz and with intensity slightly above the motor threshold. Detection was identified based on the null hypothesis of response absence rejection (significance level α = 0.05 and M = 500). The best percentages of detection were achieved in the parietal and central regions ipsilateral to the stimulation limb. C4, P4, Cz and Pz were considered the best derivations for SEP monitoring when monopolar derivations are used.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Chiappa K H (1997) Evoked potentials in clinical medicine. Raven Press, New York.
Infantosi A F C, Melges D B, Tierra-Criollo C J. (2006) Use of magnitude-squared coherence to identify the maximum driving response band of the somatosensory evoked potential. Braz J Med Biol Res 39:1593–1603.
MacDonald D B. (2001) Individually optimizing posterior tibial somatosensory evoked potential P37 scalp derivations for intraoperative monitoring. J Clin Neurophisiol 18:364–371.
Nuwer M R, Michael A, Desmedt J et al. (1994) IFCN recommended standards for short latency somatosensory evoked potentials. Report of an IFCN committee. Electroencephalogr Clin Neurophysiol 91:6–11.
McDonald D B, Stigsby B, Zayed Z A. (2004) A comparison between derivation optimization and Cz’-FPz for posterior tibial P37 somatosensory evoked potential intraoperative monitoring. Neurophysiol Clin 115:1925–1930.
Valeriani M, Restuccia D, Le Pera D et al. (2000) Scalp distribution of the earliest cortical somatosensory evoked potential to tibial nerve stimulation: proposal of a new recording montage. Neurophisiol Clin 111:1469–1477, 2000.
Valeriani M, Restuccia D, Di Lazzaro V et al. (1997) Dipolar generators of the early scalp somatosensory evoked potentials to tibial nerve stimulation in human subjects. Neurosci Lett 238:49–52.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Melges, D.B., Infantosi, A.F.C., Leite Miranda de Sá, A.M.F. (2007). Topographical distribution of the somatosensory evoked potential: an objective response detection approach. In: Müller-Karger, C., Wong, S., La Cruz, A. (eds) IV Latin American Congress on Biomedical Engineering 2007, Bioengineering Solutions for Latin America Health. IFMBE Proceedings, vol 18. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74471-9_9
Download citation
DOI: https://doi.org/10.1007/978-3-540-74471-9_9
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-74470-2
Online ISBN: 978-3-540-74471-9
eBook Packages: EngineeringEngineering (R0)