Abstract
The Electrosurgery is the technique that with the help of high voltages at high frequencies promote incision (cut) and/or hemostasis (coagulation) during surgeries. Although it has more than a century of history, many of its aspects do not have an adequate scientific explanation. For instance, undesirable electrostimulation and DC burns that eventually occurs during surgery do not have a proper explanation, so that it is difficult to minimize theses effects. In this paper it is demonstrated that whenever an electrosurgical spark is generated between the active electrode and the biological tissue a DC voltage (as higher as 180 V) is formed on the output circuit, which may explain electrostimulation and DC burns. Experimental results are also provided.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
Referências
LaCourse, J. R., Rothwell, A. D. & Selikowitz, S. M., (1993a), Development of Electrosurgery: A Historical Perspective, Bioengineering Conference, Proceedings of the 1993 IEEE Nineteenth Annual Northeast, 18–19 mar, 1993, Newark, NJ, USA, p35–36.
NBR IEC 601-1, (1994), “Equipamento Eletromédico, Parte 1: Prescrições Gerais para segurança” (equivalente à norma IEC 601-1, 1988), ABNT, Associação Brasileira de Normas Técnicas, 149p.
NBR IEC 601-2-2, 1998, “Equipamento Eletromédico, Parte 2: Prescrições particulares de Segurança para Equipamento Cirúrgico de Alta Freqüência”, ABNT, Associação Brasileira de Normas Técnicas, em abril de 1998, válida a partir de 1 de junho de 1998, 21p.
Schneider Jr., B., (2004), Estudo Teórico-prático de Parâmetros Técnicos e Fisiológicos Utilizados em Eletrocirurgia, visando a Otimização do Desenvolvimento e Performance de um Bisturi Eletrônico, Tese de Doutorado, Programa de pós-graduação em Engenharia Elétrica e Informática Industrial, CPGEI/UTFPR, Curitiba, 242p., dez.
Schneider Jr., B., and Abatti, P. J. (in press 2007) Electrical Characteristics of the Sparks Produced by Electrosurgical Devices, IEEE, Trans. On Biomedical Engineering (no prelo).
Webster, J. G., (1988), “Encyclopedia of Medical Devices and Instrumentation”, 1988, Vol.2, John Wiley & Sons, p1180–1203.
Geddes, L.A. and Roeder, R. A., (2003), De Forest and the first electrosurgical Unit, IEE, Engineering in Medicine and Biology Magazine. Jan/feb 2003. p84–87.
Geddes, L. A., Silva, L. F. and Dewitt, D. P., (1977), What’s new in electrosurgical Instrumentation?, Medical Instrumentation, Vol 11, No 6, Nov–Dec 1977.
Pearce, J.A., (1986), “Electrosurgery”, John Wiley & Sons, New York, pp270.
Dudzinski, P. J. Petrove, A. F. and Suttner, W. R., (1971), A New Electrosurgical unit. J Urol. 105: p712–713, 1971.
Leeming, M. N., Ray Jr., C. and Howland, W. S., (1970), Low-Voltage Direct-Current Burns, p1681–1684, JAMA, J. Am. Med. Assoc., Nov 30, 1970, V 214, No 9.
Chu, C., Webster, J.G., Hua, P. and AU, T., (1985), Minimizing Interference caused by Electrosurgical Units, IEEE/Seventh Annual Conference of the Engineering in Medicine and Biology Society, 1985, p775–778.
B. Schneider Jr. and P. J. Abatti, “Desenvolvimento de um Equipamento Eletrocirúrgica com Saída não Chaveada”, Revista Brasileira de Engenharia Biomédica, v. 21, n. 1, p. 17–26, abr. 2005.
Bernardi, R., Schneider JR., B.; Abatti, P. J. (2006) Kit Didático para Estudo de Eletrocirurgia. In: Congresso Brasileiro de Engenharia Biomédica 2006, 2006, São Pedro. Anais do Congresso Brasileiro de Engenharia Biomédica 2006.
Schneider Jr., B. e Abatti, P.J., (2003), Practical Procedures and Modeling for Electrosurgical Devices Transformers, IFMBE (International Federation for Medical and Biological Engineering) Proceedings, World Congress on Medical Physics and Biomedical Engineering, aug, 24–29, 2003, Sydney, Australia, 1CDROM, 4th volume, Windows 98, Camlink Digital Services.
Bowman, H. F., Cravalho, E. G. and Woods, M., (1975) Theory, Measurement, and Application of Thermal Properties of Biomaterials, Annual Review of Biophysics and Bioengineering, V-4, p43–80.
Schneider JR., B.; Abatti, P. J.; Goes, S. W. Estudo das Faíscas Eletrocirúrgica através de suas Propriedades Eletroópticas. In: Congresso Brasileiro de Engenharia Biomédica 2006, 2006, São Pedro. Anais do Congresso Brasileiro de Engenharia Biomédica 2006, 2006.
Katz, B., (1966), “Nerve, Muscle & Synapse”, McGraw-Hill, New York, New York, 193p.
Webster, J. G., (1978), “Medical Instrumentation. Application and Design”, Houghton Mifflin Company, Boston.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Schneider, B., Bernardi, R., Abatti, P.J. (2007). A Faísca Eletrocirúrgica como causa da Eletroestimulação e da Queimadura DC. In: Müller-Karger, C., Wong, S., La Cruz, A. (eds) IV Latin American Congress on Biomedical Engineering 2007, Bioengineering Solutions for Latin America Health. IFMBE Proceedings, vol 18. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74471-9_204
Download citation
DOI: https://doi.org/10.1007/978-3-540-74471-9_204
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-74470-2
Online ISBN: 978-3-540-74471-9
eBook Packages: EngineeringEngineering (R0)