Abstract
Abstract—EIT has unique potential to provide fast imaging of impedance changes in the deep brain. Both EIT sensitivity and spatial resolution can be greatly improved by increased measurement SNR. In this paper we present a prototype EIT channel with better than 70 dB SNR at excitation frequencies from 10 kHz to 100 kHz. The system is divided into three major sub-systems: digital waveform generation and demodulation, current excitation and voltage measurement. The digital sub-system, presently implemented on a Xilinx Spartan 3-1000 FPGA, provides 16- bit excitation waveform data to a DAC and subsequent reconstruction filter, which in turn provides the input to a Howland current source. The SNR of the resulting excitation current is better than 70dB. Voltage measurement is accomplished using a buffered differential amplifier followed by an anti-aliasing filter and ADC. Phase-sensitive demodulation is performed within the FPGA and the resulting phase and amplitude information returned to a PC via a USB interface.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
.Rafiei-Naeini, M. and McCann, H. (2006) A High Performance, Space Effective FPGA-Based Signal Generation and measurement System for Medical EIT(accepted). In: World Congress on Medical Physics and Biomedical Engineering, 24 Aug. -1 Sep. 2006, Seoul, South Korea.
Halter, R., Hartov, A. and Paulsen, K.D. (2005) High frequency EIT for Breast Imaging. In: 6thConference on Biomedical Applications of Electrical Impedance Tomography, University College London, London.
McLeod, C.N. and Yue, X. (2005) Abstract: OXBACT-5, A FPGA Based Wireless LAN linked EIT Data Acquisition System. In: 6thConference on Biomedical Applications of Electrical Impedance Tomography, University College London, London.
Rafiei-Naeini, M. and McCann, H. (2005) A Survey of Digital Techniques in Medical EIT. In: 6th Conference on Biomedical Applications of Electrical Impedance Tomography, University Collage London, London.
(2003) XILINX LogiCORE DDS v4.2. In: DS246(v1.5).
(2004) XILINX LogiCORE Distributed Arithmetic FIR Filter v9.0. In: DS240.
(2005) XILINX LogiCORE Multiplier Generator v7.0. In: DS255.
Saulnier, G.J. (2005) EIT Instrumentation. In: Electrical impedance tomography : methods, history and applications (Holder, D.S., ed.), pp. 67-104, Institute of Physics, Bristol and Philadelphia.
Boone K., Barber D. and Brown B. (1997) Imaging with electricity: report of the European Concerted Action on Impedance Tomography. Journal of Medical Engineering & Technology 21:201-32.
Franco S. (2002) Design with Operational Amplifiers and Analog Integrated Circuits, 3rd Edition. McGraw-Hill, New York, pp. 65-68
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Rafiei-Naeini, M., Wright, P., McCann, H. (2007). Low-Noise Measurement for Electrical Impedance Tomography. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_85
Download citation
DOI: https://doi.org/10.1007/978-3-540-73841-1_85
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-73840-4
Online ISBN: 978-3-540-73841-1
eBook Packages: EngineeringEngineering (R0)