Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 17))

  • 167 Accesses

Abstract

The paper gives an overview of historic impedance cardiography in order to describe the course of evolution as well as the shortcomings of previous calculations. One goal of all impedance cardiography (ICG) formulas is the correct estimation of electrical participating thoracic volume. A new method – continuous non-invasive cardiac output (CNCO) – is disclosed using an improved estimate of thoracic volume. The formulas are implemented in software and validated for CE and FDA certification as part of the Task Force® Monitor and other CNCO patient monitoring products of CNSystems AG, Graz, Austria.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Wright R.F., Gilbert J. (2000) Clinical Decision Making in Patients with Congestive Heart Failure: The Role of Thoracic Electrical Bioimpedance. Congest Heart Fail 6(2):27–31

    Article  Google Scholar 

  2. Silver M, Cianci P, Brennan S, Longeran-Thomas H, Ahmad F (2004) Evaluation of impedance cardiography as an alternative to pulmonary artery catherization in critically ill patients. Congest Heart Fail 10(2 suppl 2):17–21

    Article  Google Scholar 

  3. Summers R, Parrott C, Quale C, Lewis D (2004) Use of impedance cardiography in non-invasive hemodynamics to aid decision making in the initiation and titration of neurohormonal agents. Congest Heart Fail 10(2 suppl 2):28–31

    Article  Google Scholar 

  4. Strobeck J.E., Silver M., Ventura H. (2000) Impedance Cardiography: Noninvasive Measurement of Cardiac Stroke Volume and Thoracic Fluid Content. Congestive Heart Failure 6(2):3–6

    Article  Google Scholar 

  5. Drazner M.H., Thompson B., Rosenberg P.B., Kaiser P.A., Boehrer J.D., Baldwin B.J., Dries D.L., Yancy C.W.: Comparison of Impedance Cardiography with Inhasive Hemodynamic Measurements in Patients with Heart Failure Secondary to Ischemic or Nonischemic Cardiomyopathy, The American Journal of Cardiology, Vol. 89:15, pp. 993–995.

    Google Scholar 

  6. De Maria A.N., Raisinghani A.: Comparative Overview of Cardiac Output Measurement Methods: Has Impedance Cardiography Come of Age? Congestive Heart Failure, Vol. 6, No. 2, pp. 7–18.

    Google Scholar 

  7. Fortin J., Gratze G., Wach P., Skrabal F. (1997) Automated non-invasive assessment of cardiovascular function, spectral analysis and baroreceptor sensitivity for the diagnosis of syncopes. World Congress on Medical Physics and Biomedical Engineering. Med & Biol Eng & Comput 35(Supplement I):466

    Google Scholar 

  8. Gratze G., Fortin J., Holler A., Grasenick K., Pfurtscheller G., Wach P., Kotanko P., Skrabal F. (1998) A software package for non-invasive, realtime beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function. Comp in Biol & Medicine 28:121–142

    Article  Google Scholar 

  9. Fortin J., Habenbacher W., Gruellenberger R., Wach P., Skrabal F.: Real-time Monitor for hemodynamic beat-to-beat parameters and power spectra analysis of the biosignals. Proc. of the 20th Annual International Conference of the IEEE Eng in Medicine and Biology Society, 20, 1 (1998)

    Google Scholar 

  10. Fortin J., Marte W., Grüllenberger R., Hacker A., Habenbacher W., Heller A., Wagner Ch., Wach P., Skrabal F. (2006) Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Computers in Biology and Medicine 36:941-957

    Article  Google Scholar 

  11. Fortin J., Habenbacher W., Heller A., Hacker A., Grüllenberger R., Innerhofer J., Passath H., Wagner Ch., Haitchi G., Flotzinger D., Pacher R., Wach P. (2006) Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement, Computers in Biology and Medicine 36:1185-1203

    Article  Google Scholar 

  12. Atzler E., Lehmann G. (1932) Über ein neues Verfahren zur Darstellung der Herztätigkeit (Dielektrographie). Arbeitsphysiologie (Zeitschrift für die Physiologie des Menschen bei Arbeit und Sport) 5(6):636–680

    Google Scholar 

  13. Holzer W, Polzer K, Marko A (1946) RKG. Rheography. Ein Verfahren der Kreislaufforschung und Kreislaufdiagnostik. Wilhelm Maudrich, Vienna

    Google Scholar 

  14. Nyboer J. (1950) Electrical impedance plethysmography. A physical and physiologic approach to peripheral vascular study. Circulation 2:811–21

    Google Scholar 

  15. Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH (1966) Development and evaluation of an impedance cardiac output system. Aerospace Medicine 37:1208–12

    Google Scholar 

  16. Kubicek W.G., Kottke F.J., Ramos M.U., Patterson R.P., Witsoe D.A., Labree J.W., Remole W., Layman T.E., Schoening H., Garamela J.T. (1974) The Minnesota Impedance Cardiograph - Theory and Applications. Biomed Eng 9:410–6

    Google Scholar 

  17. Lamberts R, Visser KR, Zijlstra WG (1984) Impedance Cardiography. Van Gorcum, Assen, the Netherlands

    Google Scholar 

  18. Mohapatra SN, Costeloe KL, Hill DW (1977) Blood resistivity and its implications for the calculation of cardiac output by the thoracic electrical impedance technique. Intensive Care Med 3:63

    Article  Google Scholar 

  19. Quail AW, Traugott FM, Porges WL, White SW (1981) Thoracic resistivity for stroke volume calculation in impedance cardiography. J Appl Physiol 50:191

    Google Scholar 

  20. Sramek B.B.: Non-invasive measurement of cardiac output by means of electrical impedance. Proceedings of the 5th International Conference of Electrical Bioimpedance. Tokyo, Japan; p.91 (1981)

    Google Scholar 

  21. Sramek B.B., Rose D.M., Miyamoto A.: Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flow meter techniques in humans and animals. Proceeding of the 6th International Conference of Electrical Bioimpedance. Zadar, Yugoslavia; p.38 (1983)

    Google Scholar 

  22. Bernstein D.B. (1986) A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit Care Med 14:904–9

    Google Scholar 

  23. Bernstein D.B. (1986) Continuous non-invasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med 14:898–901

    Article  Google Scholar 

  24. National Heart, Lung and Blood Institute: Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults. June 17 1998

    Google Scholar 

  25. WHO: Preventing and Managing the Global Epidemic of Obesity. Report of the World Health Organization Consultation of Obesity. WHO, Geneva, June 1997

    Google Scholar 

  26. Schmidt R., Thews G.: Physiologie des Menschen, pp.547–548 (1995)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Fortin, J. et al. (2007). New Aspects of Estimating Electrical Participating Volume of the Thorax for Transthoracic Impedance Cardiography. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-73841-1_12

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-73840-4

  • Online ISBN: 978-3-540-73841-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics