Abstract
Image postprocessing is the use of imaging techniques either to derive additional information from the original axial images of a CT scan or to hide unwanted information that distracts from the clinical findings. The basis for image postprocessing is a three-dimensional image volume, which in most cases consists of a stack of individual axial images. The fundamental three-dimensional unit in this volume is called a “voxel.” Ideally, the spatial resolution of volume image data is high and isotropic, i.e., each voxel is of equal dimensions in all three spatial axes. Isotropic sub-millimeter resolution is the basis for image display in arbitrarily oriented imaging planes and advanced image postprocessing techniques. With the advent of multi-detector row CT (MDCT) and its ongoing refinement, isotropic sub-millimeter voxels can be obtained for the majority of clinical examinations, improving the diagnostic quality of image postprocessing and turning it into a vital component of medical imaging today, in particular for CT angiography (Prokop et al. 1997; Rankin 1999; Addis et al. 2001; Lawler et al. 2002).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Addis KA, Hopper KD, Iyriboz TA, Liu Y, Wise SW, Kasales CJ, Blebea JS, Mauger DT (2001) CT angiography: In vitro comparison of five reconstruction methods. Am J Radiol 177:1171–1176
Becker CR, Nikolaou K, Muders M, Babaryka G, Crispin A, Schoepf UJ, Loehrs U, Reiser MF (2003) Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT. Eur Radiol 13(9):2094–2098
Brodoefel H, Kramer U, Reimann A, Burgstahler C, Schroeder S, Kopp A, Heuschmid M (2007) Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study. AJR Am J Roentgenol 189(5):1064–1070
Buhmann S, Herzog P, Liang J, Wolf M, Salganicoff M, Kirchhoff C, Reiser M, Becker CH (2007) Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism. Acad Radiol 14(6):651–658
Carrascosa PM, Capunay CM, Garcia-Merletti P, Carrascosa J, Garcia MF (2006) Characterization of coronary atherosclerotic plaques by multidetector computed tomography. Am J Cardiol 97:598–602
Caussin C, Ohanessian A, Ghostine S, Jacq L, Lancelin B, Dambrin G, Sigal-Cinqualbre A, Angel CY, Paul JF (2004) Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound. Am J Cardiol 94:99–100
Das M, Mühlenbruch G, Helm A, Bakai A, Salganicoff M, Stanzel S, Liang J, Wolf M, Günther RW, Wildberger JE (2008) Computer-aided detection of pulmonary embolism: Influence on radiologists’ detection performance with respect to vessel segments. Eur Radiol 2008 Feb 22 [Epub ahead of print]
de Feyter PJ, Krestin GP (2005) Computed tomography of the coronary arteries, Chap. 2: Image post-processing. Taylor and Francis, London
Delhaye D, Remy-Jardin M, Teisseire A, Hossein-Foucher C, Leroy S, Duhamel A, Remy J (2006) MDCT of right ventricular function: comparison of right ventricular ejection fraction estimation and equilibrium radionuclide ventriculography, part 1. AJR Am J Roentgenol 187(6):1597–1604
Engelke C, Schmidt S, Bakai A, Auer F, Marten K (2008) Computer-assisted detection of pulmonary embolism: performance evaluation in consensus with experienced and inexperienced chest radiologists. Eur Radiol 18(2):298–307
Ferencik M, Ropers D, Abbara S, Cury RC, Hoffmann U, Nieman K, Brady TJ, Moselewski F, Daniel WG, Achenbach S (2007) Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT. Radiology 243(3):696–702
Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H (2004) Performance evaluation of a 64-slice CT-system with z-flying focal spot. Röfo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 176:1803–1810
Flohr TG, Stierstorfer K, Ulzheimer S, Bruder H, Primak AN, McCollough CH (2005) Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med Phys 32(8):2536–2547
Heuschmid M, Küttner A, Schröder S, Trebar B, Burgstahler C, Mahnken A, Niethammer M, Trabold T, Kopp AF, Claussen CD (2003) Left ventricular functional parameters using ECG-gated multidetector spiral CT in comparison with invasive ventriculography. Röfo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 175:1349–1354
Heuschmid M, Rothfuss JK, Schröder S, Fenchel M, Stauder N, Burgstahler C, Franow A, Kuzo RS, Küttner A, Miller S, Claussen CD, Kopp AF (2006) Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography. Eur Radiol 16(3):551–559
Jürgens KU, Grude M, Fallenberg EM, Opitz C, Wichter T, Heindel W, Fischbach R (2002) Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease. Am J Roentgenol 2002, 179:1545–1550
Jürgens KU, Maintz D, Grude M et al (2004) Semiautomated analysis of left ventricular function using 16-slice multidetector-row computed tomography (MDCT) of the heart in comparison to steady-state-free-precession (SSFP) cardiac magnetic resonance imaging. Eur Radiol 2004, 14:S2–272
Jürgens KU, Seifarth H, Range F, Wienbeck S, Wenker M, Heindel W, Fischbach R (2008) Automated threshold-based 3D segmentation versus short-axis planimetry for assessment of global left ventricular function with dual-source MDCT. AJR Am J Roentgenol 190(2):308–314
Kopp AF, Heuschmid M, Reinmann A, Küttner A, Beck T, Ohmer M, Burgstahler C, Brodoefel H, Claussen CD, Schröder S (2005) Evaluation of cardiac function and myocardial viability with 16-and 64-slice multidetector computed tomography. Eur Radiol 15 [Suppl 4]:D15–D20
Lawler LP, Corl FM, Fishman EK (2002) Multi-detector row and volume-rendered CT of the normal and accessory flow pathways of the thoracic systemic and pulmonary veins. Radiographics 22:S45–60
Leber AW, Knez A, White CW, Becker A, von Ziegler F, Muehling O, Becker C, Reiser M, Steinbeck G, Boekstegers P (2003) Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography. Am J Cardiol 91(6):714–718
Leber AW, Becker A, Knez A, von Ziegler F, Sirol M, Nikolaou K, Ohnesorge B, Fayad ZA, Becker CR, Reiser M, Steinbeck G, Boekstegers P (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47:672–677
Mahnken AH, Wildberger JE, Sinha AM, Dedden K, Stanzel S, Hoffmann R, Schmitz-Rode T, Günther RW (2003) Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT. Acta Radiologica 44(3):302–309
Mahnken AH, Bruder H, Suess C, Muhlenbruch G, Bruners P, Hohl C, Guenther RW, Wildberger JE (2007) Dual-source computed tomography for assessing cardiac function: a phantom study. Invest Radiol 42(7):491–498
Maizlin ZV, Vos PM, Godoy MB, Cooperberg PL (2007) Computer-aided detection of pulmonary embolism on CT angiography: initial experience. J Thorac Imaging 22(4):324–329
Marten K, Funke M, Obenauer S, Baum F, Grabbe E (2003) The contribution of different postprocessing methods for multislice spiral CT in acute pulmonary embolism. Röfo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 175(5):635–639
Napel S, Rubin GD, Jeffrey RB Jr (1993) STS-MIP: a new reconstruction technique for CT of the chest. J Comput Assist Tomogr 17(5):832–838
Pech M, Wieners G, Lopez-Hänninen E, Röttgen R, Bittner R, Engert U, Ricke J (2004) The diagnostic value of radial multiplanar reformatting (MPR) in the CT-diagnosis of pulmonary embolism. Röfo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 176(11):1576–1581
Pohle K, Achenbach S, MacNeill B, Ropers D, Ferencik M, Moselewski F, Hoffmann U, Brady TJ, Jang IK, Daniel WG (2007) Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS. Atherosclerosis 190:174–180
Prokop M, Shin HO, Schanz A, Schaefer-Prokop CM (1997) Use of maximum intensity projections in CT angiography: a basic review. Radiographics 17(2):433–451
Raman R, Napel S, Rubin GD (2003) Curved-slab maximum intensity projection: method and evaluation. Radiology 229(1):255–260
Rankin CS (1999) CT angiography (Review). Eur Radiol 9:297–310
Remy-Jardin M, Delhaye D, Teisseire A, Hossein-Foucher C, Duhamel A, Remy J (2006) MDCT of right ventricular function: impact of methodologic approach in estimation of right ventricular ejection fraction, part 2. AJR Am J Roentgenol 187(6):1605–1609
Schmermund A, Rensing BJ, Sheedy PF, Bell MR, Rumberger JA (1998) Intravenous electron-beam computed tomographic coronary angiography for segmental analysis of coronary artery stenosis. Am J Cardiol 31:1547–1554
Schoepf UJ, Schneider AC, Das M, Wood SA, Cheema JI, Costello P (2007) Pulmonary embolism: computer-aided detection at multidetector row spiral computed tomography. J Thorac Imaging 22(4):319–323
Schroeder S, Kopp A, Baumbach A, Meisner C, Kuettner A, Georg C, Ohnesorge B, Herdeg C, Claussen C, Karsch K (2001a) Noninvasive detection and evaluation of atherosclerotic coronary plaques with multi-slice computed tomography. JACC 37(5):1430–1435
Schroeder S, Flohr T, Kopp AF, Meisner C, Kuettner A, Herdeg C, Baumbach A, Ohnesorge B (2001b) Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: Results of a phantom study. JCAT 25(6):900–906
van Ooijen PM, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary Artery Imaging with Multidetector CT: Visualization Issues. Radiographics 23:e16
Vogl TJ, Nasreddin DA, Diebold T, Engelmann K, Ay M, Dogan S, Wimmer-Greinecker G, Moritz A, Herzog C (2002) Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography. Radiology 223:212–220
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Flohr, T., Ohnesorge, B. (2009). Cardiothoracic Image Postprocessing. In: Rémy-Jardin, M., Rémy, J. (eds) Integrated Cardiothoracic Imaging with MDCT. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-72387-5_3
Download citation
DOI: https://doi.org/10.1007/978-3-540-72387-5_3
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-72386-8
Online ISBN: 978-3-540-72387-5
eBook Packages: MedicineMedicine (R0)