Skip to main content
  • 1014 Accesses

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 44.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Ausgewählte Literatur

  • ASE/SCA (1996) Practice Guidelines for Perioperative Transesophageal Echocardiography. A Report by the American Society of Anesthesiologists and the Society of Cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography. Anesthesiology 84: 986–1006

    Article  Google Scholar 

  • ASE/SCA (1999) ASE/SCA Guidelines for Performing a Comprehensive Intraoperative Multiplane Transesophageal Echocardiography Examination: Recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. Anesth Analg89: 870–884

    Article  Google Scholar 

  • Bein B, Scholz J, Tonner PH (2005) Hämodynamisches Monitoring: Standards und Fehlerquellen. Anästh Intensivmed 46: 179–186

    Google Scholar 

  • Bein B, Tonner PH (2004) Fehler und Fallen des hämodynamischen Monitorings. Refresher Band Nr. 30. Diomed, Ebelsbach, S 17–22

    Google Scholar 

  • Bellomo R, Shigehiko U (2003) Cardiovascular monitoring tools: use and misuse. Curr Opin Crit Care 9: 225–229

    Article  PubMed  Google Scholar 

  • Bindels AJ et al. (2000) Relationships between volume and pressure measurements and stroke volume in critically ill patients. Crit Care 4: 193–199

    Article  PubMed  CAS  Google Scholar 

  • Bloch KE (1998) Impedance and inductance monitoring of cardiac output. In: Tobin MJ (ed) Principles and practice of intensive care monitoring. 1st edn. McGraw-Hill, New York, pp 915–930

    Google Scholar 

  • Boussat S et al. (2002) Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema. Intensive Care Med 28: 712–718

    Article  PubMed  Google Scholar 

  • Brock H et al. (2002) Monitoring intravascular volumes for postoperative volume therapy. Eur J Anaesthesiol 19: 288–294

    Article  PubMed  CAS  Google Scholar 

  • Buhre W et al. (1998) Assessment of intrathoracic blood volume. Thermo-dye dilution technique vs single-thermodilution technique. Anaesthesist 47: 51–53

    Article  PubMed  CAS  Google Scholar 

  • Chaney JC, Derdak S (2002) Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology. Crit Care Med 30: 2338–2345

    Article  PubMed  Google Scholar 

  • Connors AF Jr et al. (1996) The effectiveness of right heart catherization in the initial care of critically ill patients. JAMA 276: 889–897

    Article  PubMed  Google Scholar 

  • Eltzschig HK, Goetz AE, Schroeder TH, Ehlers R, Felbinger TW (2002) Transösophageale Echokardiographie-Perioperative Beurteilung der Herzklappen. Anaesthesist 51: 81–102

    Article  PubMed  CAS  Google Scholar 

  • Flachskamp FA (2001) Kursbuch Echokardiographie. Thieme, Stuttgart New York

    Google Scholar 

  • Flachskamp FA (2002) Praxis der Echokardiographie. Thieme, Stuttgart New York

    Google Scholar 

  • Gering H, von Bibra H (Hrsg) (1998) Echokardiographische Diagnositik bei koronarer Herzkrankheit. Steinkopff, Darmstadt

    Google Scholar 

  • Greim CA, Roewer N (2005) Transösophageale Echokardiographie für Intensivmediziner und Anästhesisten (nach den Richtlinien der DGAI, ASE/SCA und DGK). Thieme, Stuttgart New York

    Google Scholar 

  • Hainer C, Bernhard M, Scheuren K, Rauch H, Weigand MA (2006) Echokardiographie bei akuter hämodynamischer Instabilität. Anaesthesist 55: 1117–1132

    Article  PubMed  CAS  Google Scholar 

  • Hoeft A (1995) Transpulmonary indicator dilution: An alternative approach for hemodynamic Monitoring. In: Vincent JL (ed) Yearbook of intensive care and emergency medicine. Springer, Berlin Heidelberg New York Tokyo, pp 593–605

    Google Scholar 

  • Hust M (2000) Transösphageale Echo-und Doppler-Echokardiographie. Ecomed, Landsberg am Lech

    Google Scholar 

  • Janssens U (2000) Hämodynamisches Monitoring. Internist 41:995–1018

    Article  PubMed  CAS  Google Scholar 

  • Kampen J et al. (2002) Thermische Läsionen durch PiCCO-Katheter im MRT?-Fiberoptische Temperaturmessung in einem No-flow-Modell. Intensivmed Notfallmed 39(Suppl 1): 54

    Google Scholar 

  • Kimura et al. (2001) Indocyanine green elimination rate detects hepatocellular dysfunction early in septic shock and correlates with survival. Crit Care Med 29: 1159–1163

    Article  PubMed  CAS  Google Scholar 

  • Lewis FR, Pfeiffer UJ (eds) (1990) Practical applications of fiberoptics in critical care monitoring. Springer Berlin Heidelberg New York Tokyo

    Google Scholar 

  • List WF (1999) Monitoring in Anästhesie und Intensivmedizin, 2. Aufl. Springer, Berlin Heidelberg New York Tokio

    Google Scholar 

  • Loick HM, Poelaert J, Van Aken H (1997) TEE in Anästhesie und Intensivmedizin-Der diagnostische Stellenwert der transösophagealen Echokardiographie. Anaesthesist 46:504–514

    Article  PubMed  CAS  Google Scholar 

  • Magder S (1998) Cardiac output. In: Tobin MJ (ed) Principles and practice of intensive care monitoring. 1st edn. Mc-Graw-Hill, New York, pp 797–810

    Google Scholar 

  • Mahutte CK (1998) Contiunous cardiac outputmonitoring via thermal, Fick, doppler, and pulse contour methods. In: Tobin MJ (ed) Principles and practice of intensive care monitoring. 1st edn. McGraw-Hill, New York, pp 901–913

    Google Scholar 

  • McLuckie A, Bihari D (2000) Investigating the relationship between intrathoracic blood volume index and cardiac index. Intensive Care Med 26: 1376–1378

    Article  PubMed  CAS  Google Scholar 

  • Michard F, Perel A (2003) Management of circulatory and respiratory failure using less invasive volumetric and functional hemodynamic monitoring. In: Vincent JL (ed) Yearbook of intensive care and emergency medicine. Springer, Berlin Heidelberg New York Tokyo, pp 508–520

    Google Scholar 

  • Michard F, Teboul JL (2001) Usefulness of transpulmonary thermodilution to predict fluid responsiveness in humans with septic shock. Intensive Care Med 27(Suppl 2): 148

    Google Scholar 

  • Mitchell JP, Schuller D, Calandrino FS, Schuster DP (1992) Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am Rev Resp Dis 1992; 145: 990–998

    PubMed  CAS  Google Scholar 

  • Perret C et al. (1996) Measuring pressures. In: Perret C, Tagan D, Feihl F, Marini JJ (eds) The pulmonary artery catheter in critical care. 1st edn. Blackwell Science, Oxford, pp 66–93

    Google Scholar 

  • Poelaert J, Skarvan K (Hrsg) (2004) Transoesophageal echocardiography in anaesthesia and intensive care medicine, 2nd edn. BMJ Books, Blackwell, Oxford

    Google Scholar 

  • Preisman S, Pfeiffer U, Lieberman N, Perel A (1997) New monitors of intravascular volume: a comparison of arterial pressure waveform analysis and the intrathoracic blood volume. Intensive Care Med 23: 651–657

    Article  PubMed  CAS  Google Scholar 

  • Pulmonary Artery Catheter Consensus Conference (1997) Consensus statement. Crit Care Med 25: 910–925

    Article  Google Scholar 

  • Rivers EP et al. (2001) Central venous oxygen saturation monitoring in the critically ill patient. Curr Opin Crit Care 7: 204–211

    Article  PubMed  CAS  Google Scholar 

  • Sakka SG, Klein M, Reinhard K, Meier-Hellmann A (2002) Prognostic value of extravascular lung water in critically ill patients. Chest 122: 2080–2086

    Article  PubMed  Google Scholar 

  • Sakka SG, Meier-Hellmann A (2000) Evaluation of cardiac output and cardiac preload. Yearbook of Intensive Care and Emergency Medicine, Springer, Berlin Heidelberg New York Tokyo, pp 671–679

    Google Scholar 

  • Sakka SG, Meier-Hellmann A, Reinhart K (2000) Assessment of intrathoracic blood volume and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med 26: 180–187

    Article  PubMed  CAS  Google Scholar 

  • Sandham JD et al. (2003) A randomized, controlled trial of the use of pulmonary-artery catheters on high risk surgical patients. N Engl J Med 348: 5–14

    Article  PubMed  Google Scholar 

  • Sidebotham D, Merry A, Legget M (Hrsg) (2003) Practical perioperative transoesophageal echocardiography. Butterwoth Heinemann, Edinburgh

    Google Scholar 

  • Slama M, Maizel J (2006) Echocardiographic measurement of ventricular function. Curr Opin Crit Care 12: 241–248

    Article  PubMed  Google Scholar 

  • Sprung C (Hrsg) (1998) Pulmonalarterienkatheter. Methode und klinische Anwendung, 2. Aufl. Springer, Berlin Heidelberg New York Tokyo

    Google Scholar 

  • Venn R et al. (1999) The esophageal Doppler. In: Vincent JL (ed) Yearbook of intensive care and emergency medicine. 1. Aufl. Springer, Berlin Heidelberg New York Tokio, pp 482–493

    Google Scholar 

  • http://www.pulsion.com

  • http://www.pacep.org (Pulmonary Artery Catheter Education Project: PACEP)

Download references

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer Medizin Verlag Heidelberg

About this chapter

Cite this chapter

(2008). Monitoring. In: Repetitorium Intensivmedizin. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-72280-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-72280-9_2

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-72279-3

  • Online ISBN: 978-3-540-72280-9

  • eBook Packages: Medicine (German Language)

Publish with us

Policies and ethics