Abstract

Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. Retrospective ECG gating techniques have already been adapted from clinical cardiac CT that allow 3D reconstruction using retrospectively gated projection images of a multi-sweep C-arm CT scan according to the desired cardiac phase. However, it is known that retrospective gating of projection data does not provide an optimal signal-to-noise-ratio (SNR) since the measured projection data is only partially considered during the reconstruction. In this work we introduce a new reconstruction technique for cardiac C-arm CT that provides increased SNR by including additional corrected and resampled filtered back-projections (FBP) from temporal windows outside of the targeted reconstruction phase. We take advantage of several motion corrected FDK-like reconstructions of the subject to increase SNR. In the presented results, using in vivo data from an animal model, the SNR could be increased by approximately 30 percent.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   109.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   139.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Feldkamp LA, Davies LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am A1 1984:612–619.

    Google Scholar 

  2. Lauritsch G, Boese J, Wigström L, Kemeth H, Fahrig R. Towards Cardiac C-arm Computed Tomography. IEEE Trans Med Imaging 2006;25:922–934.

    Article  Google Scholar 

  3. Li T, Schreibmann E, Thorndyke B, Tillman G, Boyer A, Koong A, et al. Radiation dose reduction in four-dimensional computed tomography. Med Phys 2005;32(12):3650–3660.

    Article  Google Scholar 

  4. Prümmer M, Wigström L, Hornegger J, Boese J, Lauritsch G, Strobel N, et al. Cardiac C-Arm CT: Efficient motion correction for 4D-FBP. Procs IEEE Medical Imaging Conference, San Diego, 2006, accepted for publication.

    Google Scholar 

  5. Modersitzki J. Numerical Methods for Image Registration. Oxford University Press, 2004.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Prümmer, M., Wigström, L., Fahrig, R., Lauritsch, G., Hornegger, J. (2007). Cardiac C-Arm CT. In: Horsch, A., Deserno, T.M., Handels, H., Meinzer, HP., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2007. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-71091-2_45

Download citation

Publish with us

Policies and ethics