Bildverarbeitung für die Medizin 2007

Part of the book series: Informatik aktuell ((INFORMAT))

Abstract

In computed tomography (CT), reconstructions from cone-beam (CB) data acquired with a polychromatic X-ray device show so called beam hardening artifacts. Beam hardening artifacts are highly undesirable for a medical diagnosis, because details in the reconstructed image are severely disturbed or completely lost. In this work, we demonstrate the significant reduction of beam hardening artifacts by using an iterative reconstruction scheme which consists of a backward and a forward projector. For the backward projector, an exact reconstruction approach was used. The forward projector was extended by a polychromatic model to mimic a realistic X-ray device. The presented experiments use simulated CB data to restrict the evaluation to beam hardening artifacts. The discussion is focused on CB data acquired along a helical trajectory.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 109.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 139.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Alvarez RE, Macovski A. Energy-selective reconstruction in X-ray computerized tomography. Phys Med Biol 1976;21(5):733–744.

    Article  Google Scholar 

  2. Herman GT. Correction for beam Hardening in computed tomography. Phys Med Biol 1979;24(1):81–106.

    Article  Google Scholar 

  3. Hsieh J, Molthen RC, Dawson CA, Johnson RH. An iterative approach to beam hardening correction in cone beam CT. Med Phys 2000;27(1):23–29.

    Article  Google Scholar 

  4. Yan CH, Whalen RT, Beaupre GS, Yen SY, Napel S. Reconstruction algorithm for polychromatic CT maging: Application to beam hardening correction. IEEE Trans Med Imaging 2000;19:1–11.

    Article  Google Scholar 

  5. de Man B. Iterative Reconstruction for Reduction of Metal Artifacts in Computed Tomography. Ph.D. thesis. Katholieke Universiteit Leuven; 2001.

    Google Scholar 

  6. Van de Casteele E. Model-based Approach for Beam Hardening Correction and Resolution Measurement in Microtomography. Ph.D. thesis. Universiteit Antwerpen; 2004.

    Google Scholar 

  7. Danielsson PE, Magnusson M. Combining Fourier and Iterative Methods in Computer Tomography. Analysis of an Iterative Scheme. The 2-D Case; 2004. Report No. LiTH-ISY-R-2634, Linköping University.

    Google Scholar 

  8. Katsevich A. Theoretically exact FBP-type inversion algorithm for spiral CT. SIAM Journal on Applied Mathematics 2002;62(6):2012–2026.

    Article  MATH  MathSciNet  Google Scholar 

  9. Noo F, Pack J, Heuscher D. Exact helical reconstruction using native cone-beam geometries. Phys Med Biol 2003;48:3787–3818.

    Article  Google Scholar 

  10. Kunze H, Stierstorfer K, Härer W. Pre-processing of Projections for Iterative Reconstruction. In: The Eighth International Meeting on Fully Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine; 2005. 84–87.

    Google Scholar 

  11. Kak AC, Slaney M. Principles of Computerized Tomographic Imaging. IEEE Press; 1999.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bock, R., Hoppe, S., Scherl, H., Hornegger, J. (2007). Beam Hardening Correction with an Iterative Scheme Using an Exact Backward Projector and a Polychromatic Forward Projector. In: Horsch, A., Deserno, T.M., Handels, H., Meinzer, HP., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2007. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-71091-2_10

Download citation

Publish with us

Policies and ethics