Abstract
In recent years much progress has been made in the integration of physical transducers into clothing e.g. breathing rate, heart rate and temperature [1]. The integration of chemical sensing into textiles adds a new dimension to the field of smart clothing. Wearable chemical sensors may be used to provide valuable information about the wearer’s health, monitoring the wearer during their daily routine within their natural environment. In addition to physiological measurements chemical sensors may also be used to monitor the wearer’s surrounding environment, identifying safety concerns and detecting threats. Whether the clothes are looking into the wearer’s personal health status or looking out into the surroundings, chemical sensing calls for a novel approach to sensor and textile integration. In contrast to physical sensors, chemical sensors and biosensors depend on selective reactions happening at an active surface which must be directly exposed to a sample. Therefore issues of fluid handling, calibration and safety must be considered. This paper discusses the constraints in integrating chemical sensors into a textile substrate. Methods of fluid control using inherently conducting polymers (ICPs) are discussed and a pH textile sensor is presented. This sensor uses colorimetric techniques using LEDs controlled by a wireless platform. Some of the potential applications of wearable chemical sensors are discussed.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
P. Bonato, “Advances in wearable technology and applications in physical medicine and rehabilitation,” Journal of NeuroEngineering and Rehabilitation, vol. 2, pp. 2–5, 2005.
R. Paradiso, G. Loriga, and N. Taccini, “Wearable System for Vital Signs Monitoring,” Studies in Health Technology and Informatics, vol. 108, pp. 253–259, 2004.
R. Paradiso, G. Loriga, and N. Taccini, “A Wearable Health Care System Based on Knitted Integrated Sensors,” IEEE Transactions on Information Technology in Biomedicine, vol. 9, pp. 337–344, 2005.
P. Lukowicz, U. Anliker, J. Ward, G. Tröster, E. Hirt, and C. Neufelt, “AMON: A Wearable Medical Computer for High Risk Patients,” presented at Proceedings of the 6th International Symposium on Wearable Computers, 7–10 October, 2002.
S. Brady, L. Dunne, A. Lynch, B. Smyth, and D. Diamond, “Wearable Sensors? What is there to sense?,” Stud Health Technol Inform, vol. 117, pp. 80–88, 2006.
M. C. Carrozza, N. Croce, B. Magnani, and P. Dario, “Piezoelectric-driven stereolithography-fabricated micropump,” Journal of Micromechanics and Microengineering, vol. 5, 1995.
S. Bohm, W. Olthuis, and P. Bergveld, “A plastic micropump constructed with conventional techniques and materials,” Sensors and Actuators A: Physical, vol. 77, 1999.
A. Manz, E. Verpoorte, D. E. Raymond, C. S. Effenhauser, N. Burggraf, and H. M. Widmer, “Micro Total Analysis Systems,” P. Bergveld, Ed.: Dordrecht: Kluwer Academic Publishers, 1995, pp. 5–27.
F. C. M. Van de Pol, F. M. G. Van Lintel, M. Elwenspoek, and J. H. J. Fluitman, “A thermopneumatic micropump based on micro-engineering techniques,” Sensors and Actuators A: Physical, vol. 21, pp. 198–202, 1990.
M. C. Acero, J. A. Plaza, J. Esteve, M. Carmona, S. Marco, and J. Samitier, “Design of a modular micropump based on anodic bonding,” Journal of Micromechanics and Microengineering, vol. 7, pp. 179–182, 1997.
A. Wego and L. Pagel, “A self-filling micropump based on PCB technology,” Sensors and Actuators A: Physical, vol. 88, pp. 220–226, 2001.
S. Bohm, B. Timmer, W. Olthuis, and P. Bergveld, “Micro Total Analysis Systems,” A. van den Berg, Ed.: Dordrecht: Kluwer Academic Publishers, 2000, pp. 347–350.
S. Bart, M. Mehregany, L. S. Tavrow, and J. H. Lang, “Microfabricated electrohydrodynamic pumps,” presented at Transducers, Montreux, Switzerland, 1989.
A. Richter and H. Sandmaier, “in electrohydrodynamic micropump,” presented at Proceedings of the MEMS’ 90, 11–14 February 1990, Napa Valley, 1990.
A. Richter, A. Plettner, K. A. Hoffmann, and H. Sandmaier, “Electrohydrodynamic pumping and flow measurement,” presented at Proceedings of the MEMS’ 91, Nara, Japan,.
R. H. Baughman, I. W. Shacklette, and R. L. Elsenbaumer, “Microelectromechanical actuators based on conducting polymers,” in Topics in Molecular Organization and Engineering, Molecular Electronics, vol. 7, P. I. Lazarev, Ed.: Kluwer, Dordrecht, 1991, pp. 267.
J. D. Madden, R. A. Cush, T. S. Kanigan, and I. W. Hunter, “Fast contracting polypyrrole actuators,” Synthetic Metals, vol. 113, pp. 185–192, 2000.
S. Hara, T. Zama, W. Takashima, and K. Kaneto, “TFSI-doped polypyrrole actuator with 26% strain,” J. Mater. Chem, vol. 14, pp. 1516–1517, 2004.
Y. Wu, D. Zhou, G. M. Spinks, P. C. Innis, and G. G. Wallace, “TITAN: A Conducting Polymer Based Microfluidic Pump,” Accepted and to be published by Smart Marterials and Structures, 2005.
K. T. Lau, S. Baldwin, R. L. Shepherd, P. H. Dietz, W. S. Yerzunis, and D. Diamond, “Novel fused-LEDs devices as optical sensors for colorimetric analysis,” Talanta, vol. 63, pp. 167–173, 2004.
K. T. Lau, W. S. Yerzunis, R. L. Shepherd, and D. Diamond, “Quantitative colorimetric analysis of dye mixtures using an optical photometer based on LED array,” Sensors and Actuators B, vol. 114, pp. 819–825, 2006.
J. Frisby, “Monitoring food quality using sensor technology from harvest to home.,” Dublin City University, 2005.
F. J. Green, The Sigma Aldrich Handbook of Stains, Dyes and Indicators.
Y. Wu, “Chapter 6: Controlled release using polypyrrole coated hollow fibre,” in PhD thesis, Department of Chemistry. Wollongong: University of Wollongong, 2006.
J. Massie, K. Gaskin, P. Van Asperen, and B. Wilcken, “Sweat testing following newborn screening for cystic fibrosis.,” Pediatric Pulmonology, vol. 29, pp. 452–456, 2000.
A. Lynch, D. Diamond, and M. Leader, “CF Diagnosis using a Potentiometric Ion-Selective Electrode Array,” Analyst, vol. 125, pp. 2264–2267, 2000.
S. M. Shirreffs and R. J. Maughan, “Whole body sweat collection in humans: an improved method with preliminary data on electrolyte content.,” Journal of Applied Physiology, vol. 82, pp. 336–341, 1997.
T. Ohhashi, M. Sakaguchi, and T. Tsuda, “Human Perspiration measurement,” Physiological Measurement, vol. 19, pp. 449–461, 1998.
M. Patterson, S. Galloway, and M. A. Nimmo, “Variations in regional sweat composition in normal human males,” Experimental Physiology, vol. 85, pp. 869–876, 2000.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 International Federation for Medical and Biological Engineering
About this paper
Cite this paper
Coyle, S., Wu, Y., Lau, KT., Brady, S., Wallace, G., Diamond, D. (2007). Bio-sensing textiles - Wearable Chemical Biosensors for Health Monitoring. In: Leonhardt, S., Falck, T., Mähönen, P. (eds) 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007). IFMBE Proceedings, vol 13. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70994-7_6
Download citation
DOI: https://doi.org/10.1007/978-3-540-70994-7_6
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70993-0
Online ISBN: 978-3-540-70994-7
eBook Packages: EngineeringEngineering (R0)