Skip to main content

Optimization of Tomosynthesis Acquisition Parameters: Angular Range and Number of Projections

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Abstract

In breast tomosynthesis several projection views of the object are acquired over a limited angular range from which slice images are reconstructed. The image quality of the reconstructed slices, however, depends on the geometric acquisitions parameters and on the reconstruction algorithm. We investigated the impact of the angular range of data acquisition and number of projection views on image quality by performing 3-D cascaded linear system modeling and phantom measurements. The results show that a larger angular range not only increases resolution perpendicular to the slices but also improves the visibility of low-frequency objects since the sampling area in Fourier space is mainly limited at low-frequencies. The effect on contrast resolution is demonstrated also with clinical data sets.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Wu, T., Stewart, A., Stanton, M., McCauley, T., Phillips, W., Kopans, D.B., Moore, R.H., Eberhard, J.W., Opsahi-Ong, B., Niklason, L., Williams, M.B.: Tomographic mammography using a limited number of low-dose cone-beam projection images. Med. Phys. 30, 365–380 (2003)

    Article  Google Scholar 

  2. Bissonnette, M., Hansroul, M., Masson, M., Savard, S., Cadieux, S., Warmoes, P., Gravel, D., Agopyan, J., Polischuk, P., Haerer, W., Mertelmeier, T., Lo, J.Y., Chen, Y., Dobbins III, J.T., Jesneck, J.L., Singh, S.: Digital breast tomosynthesis using an amorphous selenium flat panel detector. In: Proc. SPIE, vol. 5745, pp. 529–540 (2005)

    Google Scholar 

  3. Ren, B., Ruth, C., Stein, J., Smith, A., Shaw, I., Jing, Z.: Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector. In: Proc. SPIE, vol. 5745, pp. 550–561 (2005)

    Google Scholar 

  4. Mertelmeier, T., Orman, J., Haerer, W., Dudam, M.: Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device. In: Proc. SPIE, vol. 6142, p. 61420F (2006)

    Google Scholar 

  5. Orman, J., Mertelmeier, T., Haerer, W.: Adaptation of image quality using various filter setups in the filtered backprojection approach for digital breast tomosynthesis. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 175–182. Springer, Heidelberg (2006)

    Chapter  Google Scholar 

  6. Zhou, J., Zhao, B., Zhao, W.: A computer simulation platform for the optimization of a breast tomosynthesis system. Med. Phys. 34, 1098–1109 (2007)

    Article  MathSciNet  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Mertelmeier, T., Ludwig, J., Zhao, B., Zhao, W. (2008). Optimization of Tomosynthesis Acquisition Parameters: Angular Range and Number of Projections. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_31

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_31

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics