Skip to main content

A CDMAM Image Phantom Software Improvement for Human Observer Assessment

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Abstract

A software tool is presented to improve the features of CDMAM image phantom by University Hospital Nijmegen. This software tool ensures that the 4-alternative forced choice method of CDMAM is actually kept, even when is being scored by highly expertise observers familiar on the test object pattern. For digital images, the developed software tool automatically changes the image position of the four corners. It can be selected a fixed rotation angle or a random one, so making impossible that any observer is able to remember the exact corner position of the target disc inside any cell. Two alternative successful algorithms have been tested. ROC curve analysis obtained by 36 observers shows that both original and computer-modified images are indistinguishable. The ROC area was 0.507±0.024 for first algorithm and 0.522±0.026 for the second one, indicating that there was no statistical difference between real and computer-modified images for both of them.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bijkerk, K.R., Lindeijer, J.M., Thijssen, M.A.O.: The CDMAM phantom: a contrast-detail phantom specifically for mammography. Radiology 185(P), 395 (1993)

    Google Scholar 

  2. Bijkerk, K.R., Thijssen, M.A.O., Arnoldussen, T.J.M.: Manual CDMAN-phantom type 3.4., Department of Diagnostic Radiology, University Medical Centre, Nijmegen, The Netherlands (2000)

    Google Scholar 

  3. Bijkerk, K.R., Thijssen, M.A.O., Arnoldussen, T.J.M.: Modification of the CDMAN Contrast-Detail Phantom for Image Quality Evaluation of Full-Field Digital Mammography Systems. In: Yaffe, M. (ed.) Proceedings of IWDM 2000, pp. 663–640. Medical Physics Publishing, Madison, Toronto (2000)

    Google Scholar 

  4. Rasband, W.S.: ImageJ, U. S. National Institutes of Health, Bethesda, Maryland, USA (1997-2008), http://rsb.info.nih.gov/ij/

  5. Karssemeijer, N., Thijssen, M.A.O.: Determination of contrast-detail curves of mammography systems by automated image analysis. In: Doi, K., Nishikawa, R.G., Scmidt, R.A. (eds.) Digital Mammography, pp. 155–160. Elsevier, Amsterdam (1996)

    Google Scholar 

  6. Rico, R., Muller, S.L., Peter, G.: Automatic scoring of CDMAN a dose study. Proc. SPIE 5034, pp. 164-173 (2003)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Prieto, G., Chevalier, M., Guibelalde, E. (2008). A CDMAM Image Phantom Software Improvement for Human Observer Assessment. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_26

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics