Skip to main content

Optimization of a Dual-Energy Contrast-Enhanced Technique for a Photon Counting Digital Breast Tomosynthesis System

  • Conference paper
Book cover Digital Mammography (IWDM 2008)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Included in the following conference series:

Abstract

We have developed a dual-energy technique for contrast-enhanced digital breast tomosynthesis using a photon-counting imaging system whereby low- and high-energy images are acquired in a single scan. A W target x-ray source is employed at 49 kV. Sn and Cu filters are used to obtain low- and high-energy images. Iodine enhanced images are calculated by applying a weighted subtraction to the logarithm of the Sn and Cu images. The optimal system configuration and Sn-Cu filter pair were assessed using theoretical modeling. The mean glandular dose was kept to 1 mSv. Optimal weighting factors (w t ) for the subtraction and SDNR between iodine-enhanced and non-enhanced breast background were calculated. Optimal w t and SDNR depend on the Sn-Cu combination and breast thickness. SDNR varies with the dose allocated among the Sn and Cu images.The optimal configuration uses Sn and Cu filters of sufficient thickness to require the maximum mAs achievable by the x-ray tube.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Schnall, M.D., Blume, J., Bluemke, et al.: Diagnostic architectural and dynamic features at breast MR imaging: multicenter study. Radiology 238(1), 42–53 (2006)

    Article  Google Scholar 

  2. Chen, S.C., Carton, A.-K., Albert, M., Conant, E.F., et al.: Initial clinical experience with contrast-enhanced digital breast tomosynthesis. Academic Radiology 14, 229–238 (2007)

    Article  Google Scholar 

  3. Carton, A.-K., Li, J., Albert, M., Chen, S., Maidment, A.D.: Quantification for contrast-enhanced digital breast tomosynthesis. In: Flynn, M.J., Hsieh, J. (eds.) Proc. Medical Imaging 2006: Physics of Medical Imaging, San Diego, vol. 6146, pp. 111–121 (2006)

    Google Scholar 

  4. Maidment, A.D.A., Albert, M., Thunberg, S., et al.: Evaluation of a Photon-Counting Breast Tomosynthesis Imaging System. In: Flynn, M.J. (ed.) Proc. SPIE, vol. 5745, pp. 572–582. SPIE, San Diego (2005)

    Chapter  Google Scholar 

  5. Maidment, A.D.A., Ullberg, C., Lindman, K., et al.: Evaluation of a photon-counting breast tomosynthesis imaging system. In: Flynn, M.J., Hsieh, J. (eds.) Proc. Medical Imaging 2006: Physics of Medical Imaging, vol. 6142, SPIE, San Diego (2006)

    Google Scholar 

  6. Boone, J.M.: Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data. Medical Physics 29(5), 869–875 (2002)

    Article  Google Scholar 

  7. Carton, A.K., Lindman, K., Ullberg, C.K., Francke, T.: Dual-energy subtraction for contrast enhanced digital breast tomosynthesis. In: Hsieh, J., Flynn, M.J. (eds.) Proc. Physics of Medical Imaging, vol. 6510. SPIE, San Diego (2007)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Carton, AK., Ullberg, C., Lindman, K., Francke, T., Maidment, A. (2008). Optimization of a Dual-Energy Contrast-Enhanced Technique for a Photon Counting Digital Breast Tomosynthesis System. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_17

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics