Summary
This paper shows an automatic registration method of the A- and B-group of MRI brain for the same patient. The time difference between recording the A-group and the B-group is equal six months. The automatic registration of the A- and B-group of MRI brain is based on the entropy and energy measures of fuzziness. First, two sequences (A- and B-group) are converted to a fuzzy representation. Then, the entropy and energy measures are employed in the NCC and GD methods. The alignment based on energy and entropy fuzzy measures shows a significant improvement in comparison with the implementation of the original image.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Brown, L.: A survey of image registration techniques, ACM Comp. Surveys 24(4), 9–18 (1992)
Brown, L., Boult, T.: Registration of planar film radiographs with computed tomography. In: Proc. MMBIA, pp. 42–51 (1996)
Czogała, E., Łȩski, J.: Application of entropy and energy measures of fuzziness to processing of ECG signal, Fuzzy sets and systems, pp. 9–18 (1997)
Deluca, A., Termini, S.: A definition of non-probabilistic entropy in the setting of fuzzy set theory. Information and Control 20, 301–312 (1972)
Gonzalez, R., Woods, R.: Digital Image Processing. Prentice-Hall, Englewood Cliffs (2002)
Łȩski, J.: A new possibilities of non-invasive electrocardiological diagnosis, Scientific Reports of the Technical University of Silesia, No 1233 (1995)
Nałȩcz, M.: Obrazowanie Biomedyczne. Biocybernetyka i Inżynieria Biomedyczna. Exit, Warszawa (2003)
Penney, G., Weeseand, J., Little, J., Desmedt, P., Hill, D., Hawkes, D.: A Comparison of Similarity Measures for Use in 2D-3D Medical Image Registration. IEEE Transactions on Medical Imaging 17(4), 586–595 (1998)
Rozentryt, P., Czogała, E., Łȩski, J.: Application of entropy and energy measures of fuzziness to heart rate variability analysis. Medical Science Monitor 2(5), 642–649 (1996)
Zarychta, P.: Cruciate Ligament Localization in T1- and T2-weighted MR Knee Images. In: IFAC Workshop PDeS 2006, pp. 203–207 (2006)
Zarychta, P.: Location and 3D visualization of the cruciate ligament in the MR knee images on the basis of fuzzy logic. PhD Thesis, Silesian University of Technology, Gliwice (2006)
Zarychta, P.: Posterior Cruciate Ligament - 3D Visualization. In: V International Conference on Computer Recognition Systems, CORES, pp. 695–702 (2007)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Zarychta, P., Zarychta-Bargieła, A. (2008). Automatic Registration of MRI Brain. In: Pietka, E., Kawa, J. (eds) Information Technologies in Biomedicine. Advances in Soft Computing, vol 47. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-68168-7_17
Download citation
DOI: https://doi.org/10.1007/978-3-540-68168-7_17
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-68167-0
Online ISBN: 978-3-540-68168-7
eBook Packages: EngineeringEngineering (R0)