Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 14))

  • 59 Accesses

Abstract

Computer assisted surgery (CAS) systems such as surgical robots and surgical navigation were clinically introduced into the field of orthopaedic surgery in the 1990’s. The first surgical robot was the ROBODOC, which milled bone for implants according to preoperative CT-based planning. More flexible navigation systems were then developed following the advent of position sensors which could be used in the surgical field. Spine and hip applications used CT-based navigation which required registration of each real object and its virtual model. Imageless navigation was used for total knee arthroplasty. These CAS systems have been reported to provide better radiographic results in pedicle screw insertion and total joint arthroplasties compared with procedures performed without them. It was initially thought both systems would help inexperienced surgeons to perform like experienced surgeons. However, eliminating human error in handling these systems is still an issue and training is necessary to bring out the benefits of their use while avoiding accidents due to misuse. On the other hand, simple CAS systems such as fluoro-navigation were developed to reduce OR time and radiation exposure. Their applications were expanded to fracture, spine, and joint surgeries. Recently, a tide of minimally invasion surgery (MIS) has come to orthopaedic surgeries and the role of CAS in the safe and accurate execution of MIS procedures has been recognized. In line with this, some navigation and robotic systems have started to be used for MIS total hip and knee arthroplasties. To enhance CAS for MIS procedures, we developed two types of systems. One uses laser guidance to control the entry point and direction of any straight surgical tools. The laser beams project directly into the surgical field indicating a point on the tissue concerned and illuminating straight tools to show the direction in which they should be operated. We used this laser guidance system clinically for acetabular reaming and cup placement in total hip arthroplasty; for femoral head preparation in hip resurfacing arthroplasty; and for pedicle screw insertion. Laser guidance increased the feasibility of navigation systems; however, 1mm and 1degree are the limits of accuracy with a hand-held tool. As a system to control of straight surgical tools more accurately than laser guidance, we developed a needle insertion robot.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 429.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 549.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

R. Magjarevic J. H. Nagel

Rights and permissions

Reprints and permissions

Copyright information

© 2007 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Sugano, N. (2007). Navigation and Robotics for Orthopaedic Surgery. In: Magjarevic, R., Nagel, J.H. (eds) World Congress on Medical Physics and Biomedical Engineering 2006. IFMBE Proceedings, vol 14. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-36841-0_9

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-36841-0_9

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-36839-7

  • Online ISBN: 978-3-540-36841-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics