Abstract
Acoustics, the science of sound, started in the 6th century BC. Ultrasound physics was discovered by Lazzaro Spallanzani in 1794 when he explained echolocation in bats, used for hunting and navigating by inaudible sound. Jacques and Pierre Curie, in 1880, discovered the piezoelectric effect, which was later used in transducers to generate and detect ultrasonic waves in air and water. In 1917, the first technological application of ultrasound was introduced by Paul Langevin to detect submarines and icebergs during the First World War.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Thijssen JM. The history of ultrasound techniques in ophthalmology. Ultrasound Med Biol. 1993;19:599–618.
Mundt G, Hughes W. Ultrasonics in ocular diagnosis. Am J Ophthalmol. 1956;41:488–98.
Oksala A, Lehtinen A. Diagnostic value of ultrasonics in ophthalmology. Ophthalmologica. 1957;134:387–95.
Yamamoto Y, Namiki R, Baba M, Kato M. A study of the measurement of ocular axial length by ultrasound echography. Acta Soc Ophthalmol Jpn. 1960;64:1333–41.
Araki M. Studies on reflective elements of the human eye by ultrasonic waves: accuracy of the measurement of ocular axial length by ultrasonic echography. J Clin Pathol. 1961;15:111–9.
Jansson F. Measurement of intraocular distances by ultrasound and comparison between optical and ultrasonic determination of the depth of the anterior chamber. Acta Ophthalmol. 1963;41:25–61.
Weinstein GW, Baum G, Binkhorst R, Troutman R. A comparison of ultrasonographic and optical methods for determining the axial length of the aphakic eye. Am J Ophthalmol. 1966;62:1194–201.
Lizzi FL, Coleman DJ. History of ophthalmic ultrasound. J Ultrasound Med. 2004;23:1255–66.
Penner R, Passmore JW. Magnetic vs nonmagnetic intraocular foreign bodies: an ultrasonic determination. Arch Ophthalmol. 1966;76:676–7.
Cowden JW, Runyan TE. Localization of intraocular foreign bodies: further experiences in ultrasonic vs radiologic methods. Arch Ophthalmol. 1969;82:299–301.
Ossoinig K. Clinical echo-ophthalmology. In: Blodi FC, editor. Current concepts in ophthalmology, vol. III. St Louis: CV Mosby Co; 1972. p. 101–30.
Baum G, Greenwood I. The application of ultrasonic locating techniques to ophthalmology, part I: reflective properties. Am J Ophthalmol. 1958;46:319–29.
Purnell EW. Ultrasound in ophthalmological diagnosis. In: Grossman C, Homes JH, Joyner C, Purnell EW, editors. Diagnostic ultrasound. New York: Plenum Press; 1966. p. 95–109.
Holasek E, Sokollu A. Direct contact, hand-held, diagnostic B-scanner. In: Proceedings of the IEEE Ultrasonic Symposium. Piscataway: Institute of Electrical and Electronics Engineers; 1972. p. 38–43.
Coleman DJ, Konig WF, Katz L. A hand-operated, ultrasound scan system for ophthalmic evaluation. Am J Ophthalmol. 1969;68:256–63.
McLeod D, Restori M. Ultrasound examination in severe diabetic eye disease. Br J Ophthalmol. 1979;63:533–8.
Bronson NR. Development of a simple B-scan ultrasonoscope. Trans Am Ophthalmol Soc. 1972;70:365–408.
Thijssen JM, Byers AL, Cloostermans MJ. Computers assisted echography: statistical analysis of A-mode video echograms obtained by tissue sampling. Med Biol Eng Comput. 1981;9:437–42.
Pavlin CJ, Sherar MD, Foster FS. Subsurface ultrasound microscopic imaging of the intact eye. Ophthalmology. 1990;97:244–50.
Coleman DJ, Silverman RH, Rondeau MJ, Lizzi FL. New perspectives: 3-D volume rendering of ocular tumors. Acta Ophthalmol Suppl. 1992;204:22.
Fisher Y, Hanutsaha P, Tong S, Fenster A, Mazarin G, Mandava N. Three-dimensional ophthalmic contact B-scan ultrasonography of the posterior segment. Retina. 1998;18:251–6.
Lieb WE. Color Doppler imaging of the eye and orbit. Radiol Clin N Am. 1998;36:1059–71.
Lizzi FL, Astor M, Liu T, Deng C, Coleman DJ, Silverman RH. Ultrasonic spectrum analysis for tissue assays and therapy evaluation. Int J Imaging Syst Technol. 1997;8:3–10.
Ferrara KW, Ostromogilsky M, Rosenberg S, Sokil-Melgar J. Parameter mapping for the detection of disturbed blood flow. Ultrasound Med Biol. 1995;21:517–25.
Silverman RH, Kruse DE, Coleman DJ, Ferrara KW. High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye. Invest Ophthalmol Vis Sci. 1999;40:1373–81.
Lizzi FL, Coleman DG, Driller J, Ostromogilsky M. Thermal model of ultrasound treatment of glaucoma. Ultrasound Med Biol. 1984;7:245–52.
Lizzi FL, Ostromogilsky M. Analytical modeling of ultrasonically induced tissue heating. Ultrasound Med Biol. 1987;13:607–18.
Lizzi FL, Driller J, Lunzer B, Kalisz A, Coleman DJ. Computer model of ultrasonic hyperthermia and ablation for ocular tumors using B-scan data. Ultrasound Med Biol. 1992;13:59–73.
De Gregorio A, Pedrotti E, Stevan G, Montali M, Morselli S. Safety and efficacy of multiple cyclocoagulation of ciliary bodies by high-intensity focused ultrasound in patients with glaucoma. Graefes Arch Clin Exp Ophthalmol. 2017;255:2429–35.
Panda PK. Review: environmental friendly lead-free piezoelectric materials. J Mater Sci. 2009;44:5049–62.
Silverman RH. Focused ultrasound in ophthalmology. Clin Ophthalmol. 2016;10:1865–75.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Agarwal, A., Maleki, A., Nguyen, Q.D. (2019). History and Principles of Ocular Ultrasonography. In: Algaeed, A., Kozak, I. (eds) Clinical Atlas of Ophthalmic Ultrasound. Springer, Cham. https://doi.org/10.1007/978-3-319-99870-1_1
Download citation
DOI: https://doi.org/10.1007/978-3-319-99870-1_1
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-99869-5
Online ISBN: 978-3-319-99870-1
eBook Packages: MedicineMedicine (R0)